SCENE function
182 PM5D/PM5D-RH V2 / DSP5D Owner’s Manual Reference section
When using Selective Recall, parameters of which only one
instance for every two adjacent odd-numbered/even-num-
bered channels/modules will be handled as follows if only
one of the channels/modules is set to Selective Recall.
PAIR
These parameters will not be recalled.
GATE STEREO LINK
COMP STEREO LINK
GEQ LINK
The LINK parameter will be forcibly turned off (link-
ing will be disabled).
DELAY GANG
ATT GANG
The GANG parameter will be recalled. If GANG is
turned on because of the recall, operation will main-
tain the difference in the DELAY/ATT parameter
values following the recall.
MS DECODE
FIXED/VARI
These parameters will not be recalled.
PAN MODE
The PAN MODE parameter will be recalled. However
if the PAN MODE would be changed by the recall from
BALANCE to any other setting, or if it would be
changed to BALANCE from any other setting, the PAN
MODE and PAN parameters will not be recalled. If the
recall causes PAN MODE to be set to GANG PAN, the
difference in PAN parameter values will be maintained
for operation following the recall.
Note
Recall Safe and Selective Recall can be used together.
Channels/parameters excluded from recall operations by
either Recall Safe or Selective Recall (or both) will not be
recalled.
Selective Recall applies when a scene is recalled in PRE-
VIEW mode.
When you recall a scene, there may be cases in which a
conflict in pairing settings between Recall Safe and Selec-
tive Recall causes the settings of a parameter to differ
between L and R channels. In such cases, the parameter
will be linked when it is next operated.
Here you can specify parameters/channels that will be
excluded from recall operations for all scenes.

ASAFE KEY MODE SELECT (Safe Key Mode

selection)

If the HA+CH button is on, Recall Safe will also turn
on/off for the HA patched to the corresponding chan-
nel when you operate the panel [RECALL SAFE] key or
the RECALL SAFE button (INPUT VIEW function CH
VIEW screen) to turn Recall Safe on/off. If the CH but-
ton is on, this will not be linked.

BOUTPUT ISOLATION

If the ON button is on, output channels and parame-
ters to be excluded from recall operations can be
memorized in SETUP memory (not included in mem-
ory card load operations) separately from the Recall
Safe function ( p.180).
RECALL SAFE screen
RECALL SAFE
1 2