PM5D/PM5D-RH V2 / DSP5D Owner’s Manual Reference section 231
Information shown
in the display
Function
menu
Global
functions
Output
functions
Input
functions
Appendices
If the recall-source and recall-destination head amp devices
have the same ID number but are assigned to different slots/
channels, the data will not be recalled to head amps of those
ID numbers.
AD8HR data can be recalled into an AD824, and AD824
data can be recalled into an AD8HR. However when AD8HR
data is recalled to an AD824, the gain settings of each chan-
nel will be converted into 6 dB units in order to match the
specifications of the AD824.
METER function
This screen contains meters that show the input level of the
input channels (input channels 1–48, ST IN channels 1–4,
FXTRN channels 1–4).
AMETERING POINT
Select one of the following as the point at which the
input level will be detected. This setting also applies to
the meters on the panel.
PRE ATT . . . . . . . . . Immediately before the
attenuator
PRE GATE . . . . . . . Immediately before the internal
gate
PRE FADER . . . . . . Immediately before the fader
POST FADER . . . . . Immediately after the fader
POST ON . . . . . . . . Immediately after the [ON] key
BCH METER ALWAYS PRE ATT
If this button is on, the input channel meters of the
panel will always show the pre-attenuator levels.
CPEAK HOLD
If this button is on, the peak level of each meter will be
held. When you turn this button off, the peak level
indication that had been held will be cleared. Peak hold
will be cleared when you change the metering point
(1). This button is linked with the [PEAK HOLD] key
in the METER section of the top panel.
INPUT METER screen
INPUT METER
1 2 3