MON/CUE function
242 PM5D/PM5D-RH V2 / DSP5D Owner’s Manual Reference section
HOUTPUT SOLO SAFE
Here you can specify output channels that will be
excluded from Solo operations. (You can specify more
than one.) The buttons correspond to the following
output channels.
Hint
Solo Safe settings and Cue on/off operations are linked for
paired channels. Solo Safe operations can be performed inde-
pendently of the scene memory.
ILevel meter
This is a peak level meter that indicates the level of the
signals output from the CUE OUT jacks. You can select
the level detection point to be immediately befor the
delay that is provided on the MONITOR/CUE bus
output (when the PRE DELAY button is on), or imme-
diately after the delay (when the POST DELAY button
is on).
JMONITOR / CUE DELAY
Here you can make settings for the delay function pro-
vided on the MONITOR/CUE bus output. Use the
knob to specify the delay time (0–1000 msec), and use
the DELAY button to switch the delay on/off. In gen-
eral, this is linked with the MONITOR/CUE DELAY
setting in the MONITOR screen. However, the differ-
ence is that in this screen, turning the AUTO BYPASS
button on lets you automatically bypass the delay when
you perform the Cue any input channels.
KCUE LEVEL
The level of the signal sent from the CUE OUT jacks is
set by the level (digital) you adjust here together with
the level (analog) adjusted by the CUE [LEVEL] knob
on the top panel of the PM5D.
LCUE OUT
Switches the cue output on/off.
MIX 1–24 MIX channels 1–24
MATRIX 1–8 MATRIX channels 1–8
STEREO A/B STEREO A/B channels
SET ALL Sets all output channels to the
Solo Safe condition
CLEAR ALL Defeats the Solo Safe setting for
all output channels
8
J
9
K
L