Cooling capacities

 

 

 

 

 

 

 

 

DB air temperature at condenser intake °C

 

 

 

 

 

 

Leaving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

30

 

35

 

40

 

45

 

 

 

water

 

 

 

 

 

Model

 

 

 

 

 

 

 

 

 

 

temp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

Consump.

Capacity

Consump.

Capacity

Consump.

Capacity

Consump.

Capacity

Consump.

 

 

 

°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

kW

W

kW

W

kW

W

kW

W

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

46 462

15.76

42 875

16.29

39 752

16.65

35 954

17.18

32 663

17.09

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

48 066

16.12

44 394

16.65

40 934

17.18

37 516

17.53

33 971

18.06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

49 669

16.29

45 998

17.00

42 200

17.71

38 824

18.06

35 406

18.60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

51 357

16.65

47 644

17.36

44 015

18.06

40 343

18.42

36 714

18.95

YLCC-H-42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

53 003

17.00

49 290

17.71

45 576

18.42

41 862

18.95

38 191

19.48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

54 818

17.36

50 978

18.06

47 180

18.77

43 255

19.30

39 499

20.01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

56 590

17.71

52 623

18.42

48 783

19.13

44 901

19.84

40 850

20.37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

58 320

18.06

54 354

18.77

50 429

19.48

46 462

20.19

43 424

20.90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

65 510

25.19

60 452

26.04

56 049

26.60

50 694

27.45

46 053

27.31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

67 771

25.75

62 594

26.60

57 715

27.45

52 896

28.02

47 898

28.87

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

70 032

26.04

64 855

27.17

59 500

28.30

54 740

28.87

49 921

29.72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

72 412

26.60

67 176

27.73

62 059

28.87

56 882

29.43

51 765

30.28

YLCC-H-62

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

74 732

27.17

69 496

28.30

64 260

29.43

59 024

30.28

53 848

31.13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

77 291

27.73

71 876

28.87

66 521

30.00

60 988

30.85

55 692

31.98

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

79 790

28.30

74 197

29.43

68 782

30.56

63 308

31.70

57 596

32.55

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

82 229

28.87

76 636

30.00

71 103

31.13

65 510

32.26

61 226

33.39

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

79 823

28.95

73 660

29.93

68 295

30.58

61 770

31.55

56 115

31.39

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

82 578

29.60

76 270

30.58

70 325

31.55

64 453

32.20

58 363

33.18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

85 333

29.93

79 025

31.23

72 500

32.53

66 700

33.18

60 828

34.16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

88 233

30.58

81 853

31.88

75 618

33.18

69 310

33.83

63 075

34.81

YLCC-H-82

 

 

 

 

 

 

 

 

 

 

 

 

9

 

91 060

31.23

84 680

32.53

78 300

33.83

71 920

34.81

65 613

35.78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

94 178

31.88

87 580

33.18

81 055

34.48

74 313

35.46

67 860

36.76

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

97 223

32.53

90 408

33.83

83 810

35.13

77 140

36.43

70 180

37.41

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

100 195

33.18

93 380

34.48

86 638

35.78

79 823

37.08

74 603

38.39

Note: The cooling and heating capacities on the tables are in accordance with a liquid temperature increase, in the indoor exchanger, of 5° C (t = 5° C). DB = Dry bulb. RH = Relative humidity.

13

Page 13
Image 13
York YLCC-h, YLCC 42/62/82/102/112, 122, 152 manual YLCC-H-42