Zebra Technologies 105Se manual $&3RZHUXVH5HSODFHPHQW

Models: 105Se 105S

1 110
Download 110 pages 13.32 Kb
Page 17
Image 17
$&￿3RZHU￿)XVH￿5HSODFHPHQW

Figure 1

$&￿3RZHU￿)XVH￿5HSODFHPHQW

A user-replaceable AC power fuse is located just above the power ON/OFF switch (see Figure 1). For a 115 VAC installation, the replacement fuse is a 3AG Fast Blow style rated at 5 Amp/250VAC. For a 230 VAC installation, the fuse is the same style but rated at 3 Amp/250 VAC. Make sure the fuse you use is correct for the voltage source.

Note: Before replacing the fuse, turn the AC power switch OFF and unplug the AC power cable.

1.To replace the fuse, insert the tip of a flatblade screwdriver into the slot in the end of the fuse holder end cap.

2.Press in slightly on the end cap and turn the screwdriver slightly counterclockwise. This disengages the end cap from the fuse holder and allows you to remove the fuse.

3.To install a new fuse, remove the old fuse and insert the new fuse into the fuse holder.

4.Push the end cap in slightly, then insert the tip of a flatblade screwdriver into the slot in the end cap and turn clockwise to engage it.

Zebra S-Series User’s Guide

9

Page 17
Image 17
Zebra Technologies 105Se manual $&3RZHUXVH5HSODFHPHQW