3$86(￿.H\￿6HOI￿7HVW

This self test is actually comprised of four individual test features, as described below.

1.The initial self test prints 15 labels at speed “A” then automatically PAUSES the printer. When the PAUSE key is pressed, an additional 15 labels print out.

2.While the printer is PAUSED, pressing the CANCEL key once alters the self test. When the PAUSE key is pressed, the printer prints 15 labels at speed “D” (“C” for the 300 dpi ).

3.While the printer is PAUSED, pressing the CANCEL key a second time alters the self test again. When the PAUSE key is pressed, the printer prints 50 labels at speed “A.”

4.While the printer is PAUSED, pressing the CANCEL key once alters the self test a third time. When the PAUSE key is pressed, the printer prints 50 labels at speed “D” (“C” for the 300 dpi ).

Note: On printers with either the rewind or peel option installed, the peel mode is activated during the first half (steps 1–4) of the PAUSE Key Self Test. On printers with a rewind option, the rewind plate must be removed for proper function of the peel sensors during the test. The first label to print says, “PEEL OPTION INSTALLED.” Each label must be manually removed from the sensor path before the next label prints. Steps 1–4 are then repeated in rewind mode.

This self test can be used to provide the test printouts required when making adjustments to the printer’s mechanical assemblies. See the sample printout in Figure 13.

Figure 13

Zebra S-Series User’s Guide

31

Page 39
Image 39
Zebra Technologies 105Se manual $86.H\6HOI7HVW