3RZHU￿2Q￿6HOI￿7HVW

A Power-On Self Test (POST) is performed each time the printer is turned ON. This test checks for proper initialization of various electronic circuits and establishes starting parameters as those stored in the printer’s memory. During this test sequence, the front panel lights turn ON and OFF to ensure proper operation. At the end of this self test, only the POWER light remains lit. If other lights are also lit, refer to “Troubleshooting” beginning on page 65.

3ULQWHU￿6HOI￿7HVWV

,QWURGXFWLRQ

These self tests produce sample labels and provide specific information that helps determine the operating conditions for the printer.

Each self test is enabled by holding in a specific front panel key or combination of keys while turning the power switch ON. Keep the key depressed until the front panel lights turn ON.

When the Power-On Self Test is completed, the selected self test automatically starts.

Note: When performing self tests, all data interface cables connected to the rear of the printer must be removed.

When canceling a self test before its actual completion, always turn the printer power OFF and then back ON to reset the printer.

When performing these self tests in the peel-off mode, the operator must remove the labels as they become available.

Unless specifically stated, all tests print in tear-off mode in tear- off printers and in peel-off mode for peel and rewind printers.

If your media is not wide enough, the test labels only print out to the edge of the label. If your media is too short, the test label continues printing on the next label.

28

Zebra S-Series User’s Guide

Page 36
Image 36
Zebra Technologies 105Se manual 3RZHU2Q6HOI7HVW, 3ULQWHU6HOI7HVWV, Qwurgxfwlrq