To adjust the lower media sensor, follow these steps:

1.Locate the lower media sensor assembly (a spring clip holding a small printed circuit board) under the rear idler roller.

2.Position the sensor so that the two brass-colored infrared emitters are under the upper sensor by sliding it in its slot.

3.Gently pull wires out of the printer frame as required. (Wires should have a little slack.)

Note: If the sensor is being moved inward and a large loop of wire develops, remove the cover from the electronics side of the printer and gently pull the wires through. It is important that the wires be properly clamped so that they are not rubbed by any belts.

Figure 25

62