Note: For Serial Interface
Printers only.
The S-Series Printer, with the RS-232 Serial Interface, uses eight miniature switches located on the rear of the printer above the signal interface cable connector. The ON/OFF positions of these switches establish some of the printer configuration parameters. Bank 1 switches must be properly positioned to establish serial data communications with the host computer. Thereafter, the position of these switches should not be changed.
Note: Parallel-interface printers do not require these configuration parameters, therefore they have no Bank 1 switches.
If these switches are in the proper position to match the communication configuration of the host computer, and the printer is not receiving data, refer to “RS-232 Cabling Requirements” on page 47 and make sure the correct interface cable is being used.
Note: The printer is fixed at 1 stop bit, so make sure that your host device is also set at 1 stop bit.