Routine Maintenance
Cleaning Schedule and Procedures
118
P1009874-003 Xi4™/RXi4™ User Guide 4/30/13
3. Using the swab from the Preventive Mainte nance Kit (part number 4 7362), wipe along the
brown strip on the printhead assembly from end to end. In place of the Preventive
Maintenance Kit, you may use a clean swab dipped in a solution of isopropyl alcohol
(minimum 90%) and deionized water (maximum 10%). Allow the solvent to evaporate.
4. While manually rotating the platen roller, clean it thoroughly with the swab. Allow the
solvent to evaporate.
5. Reload the media and the ribbon (if required).
6. Push down the printhead assembly (1), and then rotate the printhead-open lever (2)
clockwise until it locks into place.
1Swab
2Platen roller
3Printhead print elements
4Printhead-open lever
1
2
34
12