Zebra Technologies 11380100000 manual Printer Parameters Sheet 11, Set Parallel Communications

Models: 11380100200 11380100000

1 188
Download 188 pages 11.73 Kb
Page 99
Image 99

Configuration

Standard Control Panel Parameters

Table 8 • Printer Parameters (Sheet 11 of 22)

 

Language/Parameter

Action/Explanation

 

 

 

 

 

Calibrate Media and Ribbon Sensor Sensitivity

 

 

 

 

Use this procedure to adjust sensitivity of media and ribbon sensors.

 

 

Important • Follow this procedure exactly as presented. All of the

 

 

steps must be performed even if only one of the sensors requires

 

 

adjustment. You may press MINUS (-)at any step in this procedure

 

 

to cancel the process.

To perform a media and ribbon sensor calibration:

1.Press PLUS (+) to start the calibration procedure. The LOAD BACKING prompt displays.

2.Open the printhead.

3.Remove approximately 8 in. (203 mm) of labels from the backing, and pull the media into the printer so that only the backing is between the media sensors.

4.Leave the printhead open.

5.Press PLUS (+) to continue.

The REMOVE RIBBON prompt displays.

6.Remove the ribbon (if used).

7.Close the printhead.

8.Press PLUS (+) to continue.

The message CALIBRATING PLEASE WAIT displays.

The printer adjusts the scale (gain) of the signals that it receives from the media and ribbon sensors based on the specific media and ribbon combination being used. On the sensor profile, this essentially corresponds to moving the peak of the graph up or down to optimize the readings for your application.

When calibration is complete, RELOAD ALL displays.

9.Open the printhead and pull the media forward until a label is positioned under the media sensor.

10.Reload the ribbon (if used).

11.Close the printhead.

12.Press PLUS (+) to continue.

The printer performs an auto-calibration. During this process, the printer checks the readings for the media and ribbon based on the new scale established, determines the label length, and determines the print mode. To see the new readings on the new scale, print a sensor profile.

Set Parallel Communications

Select the communications port that matches the one being used by the host computer.

Default Value: BIDIRECTIONAL

Selections: BIDIRECTIONAL, TWINAX/COAX, UNIDIRECTIONAL

To change the value shown:

1.Press PLUS (+) or MINUS (-)to scroll through the options.

99

4/30/13

Xi4™/RXi4™ User Guide

P1009874-003

Page 99
Image 99
Zebra Technologies 11380100000, 11380100200 Printer Parameters Sheet 11, Calibrate Media and Ribbon Sensor Sensitivity