ZyWALL 2 and ZyWALL 2WE
Chapter 28
Troubleshooting
This chapter covers potential problems and possible remedies. After each problem description, some instructions are provided to help you to diagnose and to solve the problem. Please see the included disk for further information.
23.1 Problems Starting Up the ZyWALL
| Table | ||
PROBLEM |
| CORRECTIVE ACTION | |
|
|
| |
None of the | Make sure that you have the included power adaptor or cord connected to the ZyWALL | ||
LEDs turn on | and to an appropriate power source. | ||
when you turn |
|
| |
If the error persists, you may have a hardware problem. In this case, you should contact | |||
on the | |||
ZyWALL. | your vendor. |
| |
|
|
| |
Cannot | 1. Check to see if the ZyWALL is connected to your computer’s console port. | ||
access the |
|
| |
2. Check to see if the | VT100 terminal emulation | ||
ZyWALL via | communications program is | 9600 bps is the default speed on leaving the factory. Try | |
the console | configured correctly. The | ||
other speeds in case the speed has been changed. | |||
port. | communications software | ||
| |||
No parity, 8 data bits, 1 stop bit, data flow set to none. | |||
| should be configured as | ||
| follows: |
|
Troubleshooting |