Prestige 662H/HW Series User’s Guide
47.2.1Internal SPTGEN File Modification - Important Points to Remember
Each parameter you enter must be preceded by one “=”sign and one space.
Some parameters are dependent on others. For example, if you disable the Configured field in menu 1 (see Figure 284 ), then you disable every field in this menu.
If you enter a parameter that is invalid in the Input column, the Prestige will not save the configuration and the command line will display the Field Identification Number. Figure 285 , shown next, is an example of what the Prestige displays if you enter a value other than “0” or “1” in the Input column of Field Identification Number 1000000 (refer to Figure 284 ).
Figure 285 Invalid Parameter Entered: Command Line Example
field value is not legal
FLASH: Intel 8M *2
The Prestige will display the following if you enter parameter(s) that are valid.
Figure 286 Valid Parameter Entered: Command Line Example
Please wait for the system to write SPT text
Bootbase Version: V2.02 2/22/2001 13:33:11
RAM: Size = 8192 Kbytes
FLASH: Intel 8M *2
47.3 Internal SPTGEN FTP Download Example
1Launch your FTP application.
2Enter "bin". The command “bin” sets the transfer mode to binary.
3Get
4Edit the
451 | Chapter 47 Internal SPTGEN |