Briggs & Stratton Power Products Home Generator
Installation Manual
Generator AC Connection System
A
NOTE: Neutral is not bonded to ground at generator.
Figure 10 — System AC Connections
Grounding the System
Utility Control Circuit Connection
Control circuit interconnections consist of "Utility" leads. These two leads must be routed in conduit. Control lead functions are briefly described as follows:
•"Utility 1" and "Utility 2" deliver utility power to the generator’s circuit board, charge the battery and when utility is lost the generator will start.
Using
Fault Detection System
The light on the control panel is referred to as the Diagnostic LED. It will turn on and off in a series of blinks if certain faults are detected in the HSG. An extra LED and mounting plate is supplied so that it can be installed at a convenient indoor location.The owner will use it to observe the status of the HSG. Consult with the owner for a convienant location.
To install the remote LED panel:
•Apply the supplied decal to the supplied mounting plate.
•Push the LED through the mounting plate from the front until it snaps in place.
•Using minimum 18 AWG wire, connect the remote LED to the generator control board using supplied pin connectors. Use wire nuts to attach wire to LED leads.
•Attach mounting plate to
Refer to the section “Fault Detection System” in the Owner’s Manual for operation.
11