1 - Quick Reference

Front Panel Menus - continued

Voltage

Tran

Trigger

List

 

VOLT

Sets the input voltage

R

V:MODE

Sets the voltage mode (FIXED, LIST)

R

V:RANG

Sets the input voltage range

R

V:SLEW

Sets voltage slew rate

R

V:SLW:N

Sets voltage slew rate for negative transitions

R

V:SLW:P

Sets voltage slew rate for positive transitions

R

V:TLEV

Sets the transient input voltage

R

V:TRIG

Sets the triggered input voltage

 

TRAN

Enables/disables the transient generator (OFF/ON)

R

T:DCYC

Sets the transient duty cycle in continuous mode

R

T:FREQ

Sets the transient frequency in continuous mode

R

T:MODE

Sets the transient mode (CONT, PULSE, TOGGLE)

R

T:TWID

Sets the transient pulse width in pulse mode

 

INIT:IMMED

Initiates the trigger system

R

ABORT

Aborts the initiated trigger

 

LST:STEP

Sets the method of incrementing steps (ONCE, AUTO)

R

LST:CNT

Specifies the number of times the list is cycled

R

DWEL:0 EOL

Specifies the time period of each step

R

CURR:0 EOL

Specifies the current setting for each step

R

C:RANG:0 EOL

Specifies the current range for each step

R

C:SLEW:0 EOL

Sets the current slew rate for each step

R

C:SLW:N:0 EOL

Sets the negative current slew rate for each step

R

C:SLW:P:0 EOL

Sets the positive current slew rate for each step

R

C:TLEV:0 EOL

Sets the transient input current for each step

R

FUNC:0 EOL

Sets the list regulation mode (CURR, RES, VOLT)

R

RES:0 EOL

Specifies the resistance setting for each step

R

R:RANG:0 EOL

Specifies the resistance range for each step

R

R:SLEW:0 EOL

Sets the resistance slew rate for each step

R

R:SLW:N:0 EOL

Sets the negative resistance slew rate for each step

R

R:SLW:P:0 EOL

Sets the positive resistance slew rate for each step

R

R:TLEV:0 EOL

Sets the transient input resistance for each step

R

TRAN:0 EOL

Enables/disables the transient level for each step

R

T:DCYC:0 EOL

Sets the transient duty cycle for each step

R

T:FREQ:0 EOL

Sets the transient frequency for each step

R

T:MODE:0 EOL

Sets the mode of the transient generator (CONT, PULSE)

R

T:TWID:0 EOL

Sets the transient pulse width for each step

R

VOLT:0 EOL

Specifies the voltage setting for each step

R

V:RANG:0 EOL

Specifies the voltage range for each step

R

V:SLEW:0 EOL

Sets the voltage slew rate for each step

R

V:SLW:N:0 EOL

Sets the negative voltage slew rate for each step

R

V:SLW:P:0 EOL

Sets the positive voltage slew rate for each step

R

V:TLEV:0 EOL

Sets the transient input voltage for each step

16

Image 15
Contents USER’S Guide Certification Warranty InformationGeneral Safety SummarySafety Symbols Declaration of Conformity DeclarationPrinting History Acoustic Noise InformationTable of Contents TURN-ON Checkout 101 Front Panel -At a Glance Quick ReferenceInstrument Configuration Rear Panel At a GlanceQuick Reference Use the Function keys and Entry keys to enter a new value Front Panel Number EntryImmediate Action Keys Front Panel AnnunciatorsFront Panel Menus At a Glance Voltage Quick Reference Front Panel MenusComplete description of all programming commands Scpi Programming Commands At a GlanceQuick Reference Scpi Commands Task Where to find information Document OrientationGetting Started Map Safety Considerations Options and AccessoriesDescription Features and Capabilities Front Panel ControlsRemote Programming Constant Current CC Mode Operating ModesImmediate Current Level Software Current Limit Constant Resistance CR ModeGeneral Information Triggered Current Level Transient Current LevelConstant Voltage CV Mode Triggered Resistance LevelTransient Resistance Level Transient Voltage Level Triggered Voltage LevelToggled Transient Operation Transient OperationContinuous Transient Operation Pulsed Transient OperationTriggering a transient pulse Triggering a preset levelList Operation Triggered OperationRisetime Transition Limitation Slew Rate and Minimum Transition TimeTransition Time Slew Rate Examples Short On/Off Protection FeaturesResetting Latched Protection Input ControlOvercurrent OverpowerOvertemperature General Information OvervoltageReading Remote Programming Errors Reverse VoltageStatus Reporting Monitor Outputs Saving and Recalling SettingsExternal Control Signals Remote SensingFault Input MeasurementsPort On/Off Minimum and Maximum Measurements Power MeasurementsDC Measurements RMS MeasurementsItems Supplied CleaningInspection Damage Packaging MaterialInstalling the Modules ProcedureInstallation Channel Number Location3A. N3300A Outline Diagram Bench Operation Rack MountingDo not block the fan exhaust at the rear of the unit Power Cord Manually-Tightened ConnectorsInput Connections 6a. Manual Connector 8mm Screw Terminal Connector option UJ1Wire Considerations Stranded Copper Wire Ampere Capacity Wire Size AmpacityMaximum Wire Lengths to Limit Voltage Drops +S and -S Control ConnectorA1-A3 A11 and A10Trigger and Digital Connections Sense SwitchComputer Connections Gpib InterfaceRS-232 Interface Parallel Connections Application ConnectionsLocal Sense Connections Remote Sense Connections11. Remote Sensing 13. Zero Volt Loading Low Voltage OperationCheckout Procedure IntroductionCheckout Programming Values Case of Trouble Error MessagesSelftest Errors Selftest Error CodesFront Panel, Overall View Front Panel DescriptionFront Panel Operation System Keys Display Command FunctionImmediate Action Keys Function keysScrolling Keys Metering KeysDisplay Measurement Inpshor Input Control KeysTransient Control Keys Trigger Control KeysList Control Keys Entry Keys Entry KeysProgramming Constant Current, Voltage and Resistance Modes Using the Front Panel DisplaySet the constant current mode input Examples of Front Panel ProgrammingSet the constant voltage mode input Set the constant resistance mode inputProgramming Transient Operation Set transient operation for Continuous modeSet transient operation for Toggled mode Set transient operation for Pulse modeTmode Togg Programming ListsList Sequence Use the Meter menu for making front panel measurements Querying and Clearing Output Protection and ErrorsQuery and Clear Errors as follows Making Basic Front Panel MeasurementsSave an instrument state in location 0 as follows Setting the Gpib AddressStoring and Recalling Instrument States Set the Gpib address as followsSpecifications Specifications Table A-2. Supplemental Characteristics Specifications aN3302A N3303A N3304A N3305A N3306A SpecificationsEquipment Required Performance Test and Calibration ProceduresPerformance Test and Calibration CC Mode TestsPerformance Tests Imon Zero VerificationVoltage Programming and Measurement Accuracy Test CV Mode TestsCC Mode Regulation Test Performance Test and Calibration BCV Mode Regulation Test CR Mode Tests Resistance Range 1 Programming AccuracyResistance Range 2 Programming Accuracy Resistance Range 4 Programming Accuracy Resistance Range 3 Programming AccuracyFrequency and Duty Cycle Accuracy Transient Generator Mode TestsOutput 705TRAN on Output 705TRIGIMM Performance Test and Calibration Pulse Width AccuracyAgilent N3302A Verification Test Record Agilent N3303A Verification Test Record Agilent N3304A Verification Test Record Agilent N3305A Verification Test Record Agilent N3306A Verification Test Record Calibration Figure B-3. Voltage Calibration Table B-2 Variables and Power Source Settings CalibrationParameters Calibrated IMON, Iprog and Current Calibration Program Performance Test and Calibration Wait Performance Test and Calibration Print TABXY9,15CALIBRATING High Voltage Range Voltage Calibration ProgramPerformance Test and Calibration Resistance Calibration Program Calibrating Range Performance Test and Calibration B 100 101 Index102 Index103 Japan United States Latin AmericaCanada Australia/New Zealand Europe Asia PacificManual Updates