Installation - 3
Figure 3-6a. Manual Connector
1. Strip the back wire insulation as indicated
Wire Size | Strip back |
AWG 4 | 6 mm (0.65 in) |
AWG 6 or 8 | 13 mm (0.5 in) |
AWG 10 or smaller | 10 mm (0.4 in) |
2.AWG 4 is the maximum wire size. Stranded copper wire size, AWG 6 or 8 is the recommended wire. If you are connecting more than one wire on each connector, twist the wires to ensure a good contact when the adjustment knob is tightened.
3.Insert the wire into the connector.
WARNING To prevent accidental contact with hazardous voltages, do not extend the wire beyond the contact area inside the input connector.
4.
Caution Do not use lubricants or contact cleaners on the connectors. Certain chemical agents can damage the LEXAN material of the connector, causing the part to fail.
8mm Screw Terminal Connector (option UJ1)
The 8mm screw terminal connectors (option UJ1) are located on the rear panel and are used for connecting wires that are terminated by wire lugs to the load modules.
Two
6b). Connections are made as follows:
43