Intel ISP1100 manual Removing the Rear I/O Filler Panels

Page 47

Removing the Rear I/O Filler Panel(s)

NOTE

Perform this procedure only if you are installing PCI add-in card(s) in unused expansion slots that still have an I/O filler panel installed.

Perform this procedure to remove the rear I/O filler panel(s). Refer to Figure 26 while performing this procedure.

1.Use a Phillips screwdriver and remove the two screws (A) securing the filler panel retention bracket (B) to the top edge of the server back panel.

2.Remove the retention bracket.

3.Remove the filler panel (C) from the expansion slot for the add-in card(s) you are installing.

A

B

C

OMO9439

Figure 26. Removing the Rear I/O Filler Panel(s)

Removing/Installing Server Components

47

Image 47
Contents Intel ISP1100 Internet Server Product Guide Disclaimer Contents Configuration Software and Utilities Figures Tables System Components System ComponentsDescription Server Board FeaturesServer Board Features FeatureServer Board Connectors and Components Server Board Connectors and ComponentsBack Panel Controls, Connectors, and IndicatorsFront Panel Supported Processors ProcessorsMemory Dimm Type ECC Disabled ECC Enabled Supported Memory CharacteristicsMemory Error Detection Mode Universal Serial Bus ChipsetIDE Support Real-Time Clock, Cmos SRAM, and BatteryDiskette Drive Controller ControllerSerial Ports FanMUXCTL0 FanMUXCTL1 Heceta FAN1TACH Input Hardware MonitorKeyboard and Mouse Interface Fan Tachometer MUX Control MappingWake on LAN Scsi Hard Drive LED ConnectorIntel Pro/100+ Server 82559 Ethernet Controllers Resume on Ring Wake on Ring/Resume on RingWake on Ring SMI and NMI Routing Power ConnectorSMI and NMI Routing SpeakerFunction Fan Connector DescriptionsConnector Fan SupportFCC/Emissions Disclaimer Before You BeginElectrostatic Discharge ESD and ESD Protection Rackmount Precautions Removing the Server From the Rack Safety and Regulatory RequirementsSafety Compliance Tools and Supplies NeededRemoving/Installing the Server in the Rack Installing the Server in the RackReplacing the Cover Removing the CoverRemoving the Processor Heat Sink Removing the ProcessorRemoving the Processor Chip Installing the ProcessorRemoving the Processor Fan Removing the Processor Fan If ApplicableInstalling the Processor Chip Installing the Processor ChipInstalling the Processor Heat Sink Installing the Processor Heat SinkRemoving the Dimm Boards Removing the Dimm BoardsInstalling the Dimm Boards Installing the Dimm BoardsRemoving the Hard Drives Removing the Hard DrivesInstalling the Hard Drive in the Mounting Bracket Installing the Hard DrivesInstalling the Hard Drive in the Drive Bay Installing the Hard Drive in the Drive BayRemoving the 3.5-inch Diskette Drive Removing the 3.5-inch Diskette DriveInstalling the Drive in the Mounting Bracket Installing the 3.5-inch Diskette DriveInstalling the 3.5-inch Diskette Drive in the Drive Bay Installing the 3.5-inch Diskette Drive in the Drive BayRemoving the Filler Panel Retention Bracket Removing the PCI Add-in CardsRemoving the Riser and Add-in Cards Removing the Riser and Add-in CardsRemoving the Add-in Cards from the Riser Removing the Add-in Cards From the RiserInstalling the Rear I/O Filler Panels Installing the Rear I/O Filler PanelsRemoving the Riser Card Installing PCI Add-in CardsRemoving/Installing Server Components Installing the Add-in Cards on the Riser Installing the Add-in Cards on the RiserRemoving the Rear I/O Filler Panels Removing the Rear I/O Filler PanelsInstalling the Riser and Add-in Cards Installing the Riser and Add-in CardsVarning Replacing the Back-up BatteryReplacing the Lithium Back-up Battery Power Cord Requirements Power Up the ServerPowering Up the Server Removing/Installing Server Components Hot Keys Power-On Self-Test PostConfiguration Utilities Hot KeysDescription Using Bios SetupBios Setup Menu Bar Bios Setup Function KeysMain Menu Main MenuAdvanced Advanced Menu Advanced Menu Feature OptionsBoot Configuration Submenu Peripheral Configuration SubmenuSectors default Description IDE Configuration MenuIDE Configuration Submenu Options Boot default44/1.25MB 3.5 default Diskette Configuration SubmenuEvent Log Configuration Submenu Options Auto default Disabled defaultSecurity Menu Boot MenuBoot Boot Menu1st IDE default Last State defaultStay Off default Power On default Stay Off defaultSystem Management Menu System Management MenuSystem Management Exit Menu Upgrading the BiosPreparing for the Upgrade Exit MenuObtaining the Upgrade Utility Recovering the Bios Performing the UpgradeIntel ISP1100 Internet Server Product Guide Configuration Software and Utilities Press Resetting the SystemChecklist Initial System StartupAfter the System Has Been Running Correctly Running New Application SoftwareVerifying Proper Operation of Key System Lights More Problem Solving ProceduresPreparing the System for Diagnostic Testing Monitoring PostNo Characters Appear on Screen Specific Problems and Corrective ActionsPower Light Does Not Light Diskette Drive Activity Light Does Not Light Characters Are Distorted or IncorrectSystem Cooling Fans Do Not Rotate Properly Cannot Connect to a Server Hard Disk Drive Activity Light Does Not LightCD-ROM Drive Activity Light Does Not Light Problems with Network Problems with Application SoftwareBeeps Error message Bootable CD-ROM Is Not DetectedError and Informational Messages Error Codes and Error MessagesError Messages Description OFF Board Parity Error Addr = Index Post Intel ISP1100 Internet Server Product Guide Index