Emerson 400518-01 installation manual Low Power Connections, DC Logic Power Supply Wiring

Page 34

Safety Information

Product Overview

 

 

Installation

Diagnostics

Options and Accessories

Specification

Step 4: Low Power Connections

DC Logic Power Supply Wiring

The Epsilon drive requires a user supplied logic power supply, 24 Vdc ±10%, to power the internal logic of the drive. Use the table below to determine the current requirements of the application. Users should consider keeping logic power energized at all times because it helps prevent condensation and maintains position information in the drive.

Logic Power Supply Specification

Voltage Range

Model

Current

 

EP-P

050 A without sync encoder

24 Vdc ±10%

0.57 A with 250 mA sync encoder

 

(21.6 Vdc to 26.4 Vdc)

 

 

All EP Models except EP-P

0.31 A without sync encoder

 

 

0.38 A with 250 mA sync encoder

 

 

 

 

 

Do not wire AC line into the logic power supply input. Doing so will damage the drive.

Front View

 

 

 

L1

 

 

 

L2

 

 

 

PE

 

 

motor

R

 

R

T

 

L1

 

S

 

L2

 

 

 

PE

 

 

motor T

 

 

 

S

 

 

logic

+

logic

+

_

 

_

 

 

 

Tighten screws

to 5 in-lb.

EP204-I00-0000 9606XX-XX A1 SN 0610E014

Fuse, if required

24 Vdc

to protect wiring

Logic Power Supply

 

(User Supplied)

24 Vdc 24 V RTN

Single point PE ground

To other drives or equipment , I/O supplies, etc..

Figure 19: Logic Power Supply Wiring Diagram

For UL applications, the logic power supply must be a UL recognized or UL listed limited voltage/limited energy or limited voltage/limited current supply, or a limited voltage supply with overcurrent protection appropriate for the wiring and not to exceed 12 A. Isolate line connected circuits from low voltage circuits.

For applications to meet the EU Low Voltage Directive, an approved 24V supply must be used and the negative side must be grounded to PE. PELV circuits must have protective separation for 300 V system voltage from mains connected circuits, including separation between encoder circuits and motor power wiring. If all circuits connected

22

Image 34
Contents Epsilon EP Drive Page Epsilon EP Drive Installation Manual Reference Materials Safety Precautions General warning Underwriters Laboratories Listed Listed 51Y8 IND. CONT. EQDrive Overload Protection CE Declaration of Conformity ViiViii Table of Contents Specifications Diagnostics and TroubleshootingOptions and Accessories IndexEpsilon EP Drive Product OverviewProduct Overview Electromagnetic Compatibility EMC Basic Installation GuidelinesInstallation Achieving Low Impedance ConnectionsElectrostatic Discharge ESD Protection Wiring NotesEnvironmental Considerations Panel Layout Nema EnclosureOutside Enclosure Cable to Enclosure ShieldingInside Enclosure AC Line Filters Mechanical InstallationAC Line Filter Installation Notes Epsilon EP Schaffner Control Techniques RatingMechanical Drawing for Epsilon Base and Indexing Drives Drive Model Dimension a Minimum Panel Width Inches mm Mechanical Drawing for Epsilon Programming DriveHigh Power Connections System GroundingAC Power Requirements AC Supplies not Requiring TransformersAC Supplies Requiring Transformers Earth Grounded Delta Distribution Transformer, 240 Vac 3ØTo Fusing Single Phase Power Supply Connections Transformer SizingDrive/Motor Combination Suggested KVA Rating Line Fusing and Wire Size LPN-RK-10SPAC Input Power Connections Operation on DC Input SupplyShunt Control External Shunt Electrical InstallationShunt Resistor Kit Installation External Shunt ResistorMotor Power Wiring NT and MG MotorsEpsilon EP NT/MG Motor Power Wiring Diagram XV Motor Power Wiring Front ViewLogic Power Supply Specification Low Power ConnectionsDC Logic Power Supply Wiring Voltage Range Model CurrentConnection of Encoder Commutation Signals to the Drive Motor Feedback Wiring J6Connection of Encoder Quadrature and Marker Signals Motor Overtemp WiringXV 40-80 mm Motor XV 130 mm MotorMotor Brake Wiring Epsilon EP to NT or MG Motor Brake Wiring DiagramInput/Output and Drive Enable Wiring XV 40mm-80mmConnector J3 Functions O Connector J3 Functions Analog/Sync Output Connector J5 STI-SNCOAFunction Pin Numbers Electrical Characteristics Sync Input Connector J10 Function Pin Number Electrical CharacteristicsAnalog Command Wiring Encoder Output Signal WiringConnector Shell Drive J5Pulse Mode Wiring, Differential Inputs Ns MinimumPulse Mode Wiring, Single Ended Inputs CCWMaster/Slave Encoder Connections Communication Cables CommunicationsPin Function Epsilon EP Serial Communication Connector Ethernet Port Serial Communications SpecificationsModbus Communications DeviceNet PortInstallation Status Codes Diagnostic DisplayDiagnostics and Troubleshooting Display Indication Status DescriptionFault Codes Display Fault Action to Reset Bridge Disabled Fault Descriptions Flash InvalidHigh DC Bus Threshold Low DC Bus ThresholdTravel Limit + Drive Faults Diagnostic Analog Output Test PointsChannel Analog/Sync Output Connector J5 Pin# Rebooting the Drive Viewing Active Drive FaultsResetting Faults Options and Accessories Epsilon EP Drive OptionsSTI-24IO STI-SNCOA STI-SNCI STI-ENC Options and Accessories Epsilon EP Specifications SpecificationsControl Inputs Pulse ModeEncoder Output Signal Control OutputsCooling Method Fault Detection CapabilityDrive Weights EnvironmentalEpsilon EP Drive Dimensions Drive Model Dimension a Dimension B Shown in inches/mmCable Diagrams EIO26 CableXV Motor Cables XTMDS-XXX CableXCMDS-XXX XCMDBS-XXX XTBMS-XXX +24VXEFTS-XXX Cable PINXEFCS-XXX Cable CMDS-XXX Cable NT and MG Motor CablesCMMS-XXX Cable Socket Specifications CBMS-XXX CableEFCS-XXX Cable Sync Cables SNCFLOA-XXXSNCMD-815-XXX SNCMD-89-XXX Communications Cables ESA-SP-485-XXXIndex Page