Safety Information | Product Overview |
|
|
Installation
Diagnostics
Options and Accessories
Specification
Step 4: Low Power Connections
DC Logic Power Supply Wiring
The Epsilon drive requires a user supplied logic power supply, 24 Vdc ±10%, to power the internal logic of the drive. Use the table below to determine the current requirements of the application. Users should consider keeping logic power energized at all times because it helps prevent condensation and maintains position information in the drive.
Logic Power Supply Specification
Voltage Range | Model | Current | |
|
| 050 A without sync encoder | |
24 Vdc ±10% | 0.57 A with 250 mA sync encoder | ||
| |||
(21.6 Vdc to 26.4 Vdc) |
|
| |
All EP Models except | 0.31 A without sync encoder | ||
| |||
| 0.38 A with 250 mA sync encoder | ||
|
| ||
|
|
|
Do not wire AC line into the logic power supply input. Doing so will damage the drive.
Front View
|
|
| L1 |
|
|
| L2 |
|
|
| PE |
|
| motor | R |
| R | T | |
| L1 |
| S |
| L2 |
|
|
| PE |
|
|
motor T |
|
| |
| S |
|
|
logic | + | logic | + |
_ | |||
| _ | ||
|
|
|
Tighten screws
to 5 in-lb.
Fuse, if required | 24 Vdc | |
to protect wiring | ||
Logic Power Supply | ||
| (User Supplied) |
24 Vdc 24 V RTN
Single point PE ground
To other drives or equipment , I/O supplies, etc..
Figure 19: Logic Power Supply Wiring Diagram
For UL applications, the logic power supply must be a UL recognized or UL listed limited voltage/limited energy or limited voltage/limited current supply, or a limited voltage supply with overcurrent protection appropriate for the wiring and not to exceed 12 A. Isolate line connected circuits from low voltage circuits.
For applications to meet the EU Low Voltage Directive, an approved 24V supply must be used and the negative side must be grounded to PE. PELV circuits must have protective separation for 300 V system voltage from mains connected circuits, including separation between encoder circuits and motor power wiring. If all circuits connected
22