Installation
Operating Mode Jumper
This jumper determines the operating mode. Place the jumper over the pins that correspond to the desired mode.
•Charge Control (PV Charge Controller or Diversion Controller)
•Load Control (Load Controller)
Factory default setting is Charge Control mode.
Charge/Load
Control
Jumper | Charge Control Mode |
| |
| Load Control Mode |
Figure 2-6 Mode of Operation Jumper
Voltage Jumper
The voltage jumper determines the voltage of the system that the controller will be used with. To set the voltage, place the jumper over the two pins adjacent to the legend for the voltage of your system: 12, 24, 48. Factory setting is 12 volts for the C35, C40, and C60.
C40 Models
12 Volt Position
24 Volt Position
48 Volt Position
C35 and C60
Models
12 Volt Position
24 Volt Position
Figure 2-7 Voltage Selection Jumper