Operation
Equalization Mode Indication (Red/green)
Be sure to read all cautions and warning regarding equalization charging batteries BEFORE allowing an equalization charge to occur. Damage to batteries can occur.
Alternating Red and Green
The controller is in the EQUALIZE mode.
It will automatically stop the equalization process after accumulating two hours of operation at a voltage above the BULK setting.
The user can manually stop the equalization process at any time by pressing the reset switch until the status LED stops alternating red and green.
Load Control Indications (Red)
The flashing rate of the LED indicates the controller’s stage of operation and approximate battery voltage.
Blinking Red
As battery voltage approaches the LVD setting, the LED will blink red several times (up to five) and then pause providing an indication of battery voltage. Refer to Table
Solid Red
The controller is in the Load Control mode and the battery voltage has reached the Low Voltage Disconnect (LVD) setting. After a
58 |