Configuring the
Automatic/Manual Battery Equalization (EQ) and Low Voltage Reconnect (LVR) Jumper
Depending on the mode of operation chosen, this jumper enables:
•automatic or manual battery equalization (Charge Control mode), or
•automatic or manual reconnect in the event of low voltage event (Load Control mode).
When AUTO is enabled in the Charge Control mode, the unit will perform an equalization charge every 30 days. This can be done manually by using Reset Switch on the side of the controller chassis.
When AUTO is enabled in Load Control mode, the unit will reconnect automatically when voltage at the BATTERY POSITIVE terminal exceeds the LVR setting. This can also be done manually by using Reset Switch on the side of the controller chassis.
The factory default setting is MANUAL EQUALIZATION (Charge Control mode).
Place the jumper over the pins for the desired selection.
EQ/LVR Jumper
MANUAL
AUTO
Figure 2-8 EQ/LVR Jumper and Reset Switch
See “Error Mode Indication (Orange)” on page 59 for instructions on how to use the Reset Switch in relation to this function.