Operating Modes
Bulk Stage
During this stage, the batteries are charged at the bulk voltage setting and maximum current output of the DC source. When the battery voltage reaches the bulk voltage setting, the controller activates the next stage (absorption).
Absorption Stage
During this stage, the voltage of the battery is held at the bulk voltage setting until an internal timer has accumulated one hour. Current gradually declines as the battery capacity is reached.
Float Stage
During this stage, the voltage of the battery is held at the float voltage setting. Full current can be provided to the loads connected to the battery during the float stage from the PV array. When battery voltage drops below the float setting for a cumulative period of one hour, a new bulk cycle will be triggered.
|
| Bulk Stage | Absorption Stage | Float Stage |
Charging |
|
| Bulk Volts Setting |
|
Started |
|
|
|
|
|
|
| Absorption Time | Float Volts Setting |
DC Voltage | Increasing Voltage | Constant Voltage | Reduced Voltage | |
0 volts |
|
|
|
|
|
| Max Amps |
|
|
DC Current | Constant Current | Reducing Current | Reduced Current | |
0 amps |
|
|
|
|
Time |
|
|
|
|
Figure |
|
|
5 |