Temperature Compensation
Terminating the Equalization Process
To stop the equalization process, press the reset switch on the right side of the unit until the status LED stops alternating between red and green.
If the equalization process was shorter than one hour, the controller will continue with a bulk charge cycle and then hold the battery at the bulk setting for one hour (the absorption stage) before returning to the float setting.
Front Panel LED (flashes red/green during equalization)
Press Reset Switch until LED stops alternating between red and green
Figure 2-19 Terminating the Equalization Charge
Temperature Compensation
Important: If using the
•Do NOT compensate the settings.
•Do not install the Battery Temperature Sensor.
For optimal battery charging, the Bulk and Float charge rates should be adjusted according to the temperature of the battery. When battery charging voltages are compensated based on temperature, the charge voltage will vary depending on the temperature around the batteries.
33 |