Installation
Adjusting the C-Series Voltage Settings
The charging voltage setpoints and voltage reconnect/ disconnect setting of the controller are adjustable using two rotary potentiometer controls. The knobs are removable to reduce the likelihood of accidental
Calibrated scales, shown as scale marks, are provided to allow setting of the control without requiring the use of a digital voltmeter.
For more information regarding bulk and float charging voltages, see
Setting indicator |
|
Scale Marks | Potentiometers |
|
Figure 2-9 Bulk and Float Charge Potentiometers (pots)
Setting Voltage Parameters for Charge Control Mode
To set the controller to a specific voltage, point the setting indicator at the scale mark representing the desired voltage.
The potentiometer scale for BULK charge voltage is calibrated as follows:
•
•
•
22 |