Installation
PV Charge Control Mode Wiring
The procedure below is illustrated in Figure 2-23.
WARNING: Shock Hazard
PV arrays generate voltage whenever light strikes the surface of the array. Before connecting the
To connect the C-Series controller as a charge controller:
1.Connect the PV array’s positive (+) output to the PV array disconnect.
2.Route another (+) cable from the other end of the RE disconnect to the PV GFP.
3.Route another (+) cable from the same switch in the PV GFP to the terminal marked PV POS/LOAD in the
4.Connect the PV array’s negative
5.Connect another negative
6.Route a negative
7.Connect a positive (+) cable from terminal marked BAT POS to the battery disconnect in the DC disconnect.
8.Connect a second positive (+) cable to the other side of the battery disconnect in the DC disconnect and connect to the positive (+) battery terminal.
9.Connect the negative
10.Tighten per torque requirements outlined on page 39. Allow a little slack on the cables within the controller and secure the wiring with strain reliefs.
44 |