Cabletron Systems 9C300-1 manual System Humidity, System Voltages, Internal Operating Temperature

Page 16

9C300-1 Environmental Module Operation

System Humidity

The 9C300-1 Environmental Module monitors the non-condensing humidity level of the MMAC-Plus. The results of the monitoring are available to the network manager via LCD, as well as local and remote management. The humidity levels are displayed as shown in Table 3-2.

Table 3-2. System Humidity

Humidity

LCD Display

 

 

 

 

0–45%

STATIC RISK

 

 

46–94%

NORM (normal)

 

 

95% and above

MOIST

 

 

System Voltages

The 9C300-1 Environmental Module monitors specific system power parameters to ensure that they are within acceptable limits. The power parameters monitored from the backplane are the 48 volt DC System Power Bus and the INB Termination Power Bus. The power parameter monitored within the Environmental Module is the 12 volt internal line. The results of the monitoring are available to the network manager via LCD, as well as local and remote management. Voltages above or below the acceptable voltage limits cause an alarm to be sent to the network manager. Table 3-3summarizes these acceptable voltage limits.

Table 3-3. Acceptable Voltage Limits

Description

Acceptable Voltage Limits

 

 

 

 

48 volt DC System Power Bus

From 40 volts to 59 volts

 

 

INB Termination Power Bus

From 3.1 volts to 5 volts

 

 

12 volt internal line

From 11 volts to 13 volts

 

 

Internal Operating Temperature

The 9C300-1 Environmental Module monitors its own internal operating temperature by comparing its current temperature to the ambient temperature and programmed rise temperatures to determine current temperature status. If the temperature of the Environmental Module exceeds normal operating limits, an alarm is sent to the network manager. In addition, if the ambient temperature sensor fails, pre-established temperature ranges have been programmed to ensure proper internal temperature monitoring.

3-4

Image 16
Contents MMAC-Plus 9C300-1 Environmental Module User’s Guide Page Page FCC Notice DOC NoticeContents Chapter Specifications Appendix B Uninterruptible Power Supply UPSAppendix a Epim Specifications Using This Manual 9C300-1 Environmental ModuleSystem Cooling FeaturesOut-of-Band Management Environmental/Power Monitoring Related ManualsFlash Eeprom Hot SwappingGetting Help Installing the 9C300-1 Environmental Module Installing the 9C300-1 Environmental ModuleInstalling the 9C300-1 Environmental Module 9C300-1 Environmental Module Operation Monitoring FunctionsExternal Ambient Temperature Temperature Range LCD DisplayFan Speed 9C300-1 Environmental Module and Fan TrayInternal Operating Temperature System HumiditySystem Voltages Humidity LCD DisplayLanview LEDs LED Color State DescriptionOut-of-Band Management COM1 and COM2 Ports Pin DescriptionEthernet Port Interface Module Epim LCD and KeypadNon-Interactive Mode Screens Non-Interactive ModeSystem Screen Utilization Screen Environment ScreenPower Screen System Banner ScreenInteractive Mode Interactive Mode ScreensAlarm Screen Main ScreenENV Supplies Installed 2 PWR Redundancy Status 1 on 2 on Exit Power Supply Specific ScreenCommunications Screen Diagnostic Module Selection Screen Diagnostic Results ScreenBBU Screen Module Selection ScreenFault Module Specific ScreenModule Environment Screen Module Memory ScreenModule Backplane Screen Environmental Module Specific ScreenEnvironmental Module Environment Screen LCD Contrast Adjustment Screen 9C300-1 Environmental Module Operation Safety ServiceDimensions WeightPhysical EnvironmentalEpim Specifications IntroductionEPIM-F1 and EPIM-F2 Parameter Typical Value Worst Worst Case BudgetEPIM-F1 and EPIM-F2 EPIM-F3 Parameter Typical Minimum Maximum Connector Type GroundingEPIM-A and EPIM-X AUI Port Pin Number RepresentsEpim Specifications Uninterruptible Power Supply UPS Connecting a UPS to an EMUninterruptible Power Supply UPS Configuring COM Port for UPSVerifying Configuration Monitoring UPSUninterruptible Power Supply UPS