Cabletron Systems 9C300-1 manual EPIM-F1 and EPIM-F2

Page 41

EPIM-F1 and EPIM-F2

Table A-2. Transmitter Power

Parameter

Typical Value

Worst

Worst Case

Typical

Case

Budget

Budget

 

 

 

 

 

 

 

 

 

 

 

 

50/125 ∝m

-13.0 dBm

-15.0 dBm

13.0 dB

17.5 dB

fiber

 

 

 

 

 

 

 

 

 

62.5/125 ∝m

-10.0 dBm

-12.0 dBm

16.0 dB

20.5 dB

fiber

 

 

 

 

 

 

 

 

 

100/140 ∝m

-7.0 dBm

-9.0 dBm

19.0 dB

23.5 dB

fiber

 

 

 

 

 

 

 

 

 

Error Rate

Better than 10-10

 

 

 

 

 

 

 

 

NOTE

The transmitter power levels and receive sensitivity levels listed are Peak Power Levels after optical overshoot. A Peak Power Meter must be used to correctly compare the values given above to those measured on any particular port. If Power Levels are being measured with an Average Power Meter, then 3 dBm must be added to the measurement to correctly compare those measured values to the values listed (i.e., -30.5 dBm peak = -33.5 dBm average).

A-3

Image 41
Contents MMAC-Plus 9C300-1 Environmental Module User’s Guide Page Page DOC Notice FCC NoticeContents Appendix a Epim Specifications Appendix B Uninterruptible Power Supply UPSChapter Specifications 9C300-1 Environmental Module Using This ManualOut-of-Band Management FeaturesSystem Cooling Related Manuals Environmental/Power MonitoringFlash Eeprom Hot SwappingGetting Help Installing the 9C300-1 Environmental Module Installing the 9C300-1 Environmental ModuleInstalling the 9C300-1 Environmental Module Monitoring Functions 9C300-1 Environmental Module OperationTemperature Range LCD Display External Ambient Temperature9C300-1 Environmental Module and Fan Tray Fan SpeedSystem Humidity Internal Operating TemperatureSystem Voltages Humidity LCD DisplayLED Color State Description Lanview LEDsOut-of-Band Management Pin Description COM1 and COM2 PortsLCD and Keypad Ethernet Port Interface Module EpimSystem Screen Non-Interactive ModeNon-Interactive Mode Screens Environment Screen Utilization ScreenSystem Banner Screen Power ScreenInteractive Mode Screens Interactive ModeMain Screen Alarm ScreenENV Power Supply Specific Screen Supplies Installed 2 PWR Redundancy Status 1 on 2 on ExitCommunications Screen Diagnostic Results Screen Diagnostic Module Selection ScreenModule Selection Screen BBU ScreenModule Specific Screen FaultModule Memory Screen Module Environment ScreenEnvironmental Module Specific Screen Module Backplane ScreenEnvironmental Module Environment Screen LCD Contrast Adjustment Screen 9C300-1 Environmental Module Operation Service SafetyWeight DimensionsPhysical EnvironmentalIntroduction Epim SpecificationsParameter Typical Value Worst Worst Case Budget EPIM-F1 and EPIM-F2EPIM-F1 and EPIM-F2 EPIM-F3 Parameter Typical Minimum Maximum Grounding Connector TypePin Number Represents EPIM-A and EPIM-X AUI PortEpim Specifications Connecting a UPS to an EM Uninterruptible Power Supply UPSConfiguring COM Port for UPS Uninterruptible Power Supply UPSMonitoring UPS Verifying ConfigurationUninterruptible Power Supply UPS