Cabletron Systems 9C300-1 manual Module Environment Screen, Module Memory Screen

Page 32

9C300-1 Environmental Module Operation

The Module Environment Screen

Select <ENV> at the Module Specific Screen, as shown in Figure 3-24,to display environmental parameters for the specific module.

Line 1 of the Module Environment Screen, as shown in Figure 3-25,identifies the selected module by chassis slot location.

Line 2 displays the measured input voltage from the 48 volt system power bus to the module’s DC-to-DC converter. The MMAC-Plus power supply provides voltage to the module via a chassis backplane. The converter’s 5 volt output line is also shown on line 2.

Line 3 displays the module’s current temperature in Fahrenheit and Celsius. The temperature is qualified as either COLD, COOL, NORM (normal), WARM, or HOT based on system parameters.

MODULE xx

INPUT PWR: xx.xV, OUTPUT PWR x.xV TEMP: xxx°F, xx°C NORM

<EXIT>

Figure 3-25. The Module Environment Screen

Select <EXIT> to return to the Module Specific Screen.

The Module Memory Screen

Select <MEMORY> at the Module Specific Screen, as shown in Figure 3-24,to view the memory configuration of a selected module.

Line 1 of the Module Memory Screen, as shown in Figure 3-26,identifies the module, and its current CPU loading factor, expressed as a percent of capacity.

Line 2 displays the amount of FLASH memory (in megabytes) installed on the module.

Line 3 displays the amount of SHARED DRAM and LOCAL DRAM (in megabytes) installed on the module.

MODULE xx, CPU LOAD xxx%

FLASH xx MB

SHARED DRAM xx MB LOCAL DRAM xx MB <EXIT>

Figure 3-26. The Module Memory Screen

Select <EXIT> to return to the Module Specific Screen.

3-20

Image 32
Contents MMAC-Plus 9C300-1 Environmental Module User’s Guide Page Page FCC Notice DOC NoticeContents Appendix a Epim Specifications Appendix B Uninterruptible Power Supply UPSChapter Specifications Using This Manual 9C300-1 Environmental ModuleOut-of-Band Management FeaturesSystem Cooling Environmental/Power Monitoring Related ManualsFlash Eeprom Hot SwappingGetting Help Installing the 9C300-1 Environmental Module Installing the 9C300-1 Environmental ModuleInstalling the 9C300-1 Environmental Module 9C300-1 Environmental Module Operation Monitoring FunctionsExternal Ambient Temperature Temperature Range LCD DisplayFan Speed 9C300-1 Environmental Module and Fan TrayInternal Operating Temperature System HumiditySystem Voltages Humidity LCD DisplayLanview LEDs LED Color State DescriptionOut-of-Band Management COM1 and COM2 Ports Pin DescriptionEthernet Port Interface Module Epim LCD and KeypadSystem Screen Non-Interactive ModeNon-Interactive Mode Screens Utilization Screen Environment ScreenPower Screen System Banner ScreenInteractive Mode Interactive Mode ScreensAlarm Screen Main ScreenENV Supplies Installed 2 PWR Redundancy Status 1 on 2 on Exit Power Supply Specific ScreenCommunications Screen Diagnostic Module Selection Screen Diagnostic Results ScreenBBU Screen Module Selection ScreenFault Module Specific ScreenModule Environment Screen Module Memory ScreenModule Backplane Screen Environmental Module Specific ScreenEnvironmental Module Environment Screen LCD Contrast Adjustment Screen 9C300-1 Environmental Module Operation Safety ServiceDimensions WeightPhysical EnvironmentalEpim Specifications IntroductionEPIM-F1 and EPIM-F2 Parameter Typical Value Worst Worst Case BudgetEPIM-F1 and EPIM-F2 EPIM-F3 Parameter Typical Minimum Maximum Connector Type GroundingEPIM-A and EPIM-X AUI Port Pin Number RepresentsEpim Specifications Uninterruptible Power Supply UPS Connecting a UPS to an EMUninterruptible Power Supply UPS Configuring COM Port for UPSVerifying Configuration Monitoring UPSUninterruptible Power Supply UPS