Cabletron Systems 9C300-1 manual Related Manuals, Environmental/Power Monitoring, Flash Eeprom

Page 9

Related Manuals

Environmental/Power Monitoring

The 9C300-1 Environmental Module monitors and reports chassis power parameters, ambient chassis temperature, chassis humidity, temperature of the Environmental Module itself, as well as the status and speed of the chassis cooling fans.

Flash EEPROM

The capability of downloading future firmware upgrades has been built into the 9C300-1 Environmental Module.

Hot Swapping

The 9C300-1 Environmental Module can be removed from the chassis while the MMAC-Plus is running without interrupting network performance.

LANVIEW® LEDs

Two LEDs, STATUS and ALARM, are built into the front of the 9C300-1 Environmental Module. These LEDs indicate the status of the Environmental Module and the presence or absence of system alarms.

Related Manuals

The manuals listed below should be used to supplement the procedures and technical data contained in this manual.

MMAC-Plus Installation Guide

MMAC-Plus Operations Guide

MMAC-Plus 9C214-AC Power Supply User’s Guide

In addition, each Interface Module has a user’s guide.

1-3

Image 9
Contents MMAC-Plus 9C300-1 Environmental Module User’s Guide Page Page DOC Notice FCC NoticeContents Appendix B Uninterruptible Power Supply UPS Chapter SpecificationsAppendix a Epim Specifications 9C300-1 Environmental Module Using This ManualFeatures System CoolingOut-of-Band Management Related Manuals Environmental/Power MonitoringFlash Eeprom Hot SwappingGetting Help Installing the 9C300-1 Environmental Module Installing the 9C300-1 Environmental ModuleInstalling the 9C300-1 Environmental Module Monitoring Functions 9C300-1 Environmental Module OperationTemperature Range LCD Display External Ambient Temperature9C300-1 Environmental Module and Fan Tray Fan SpeedSystem Humidity Internal Operating TemperatureSystem Voltages Humidity LCD DisplayLED Color State Description Lanview LEDsOut-of-Band Management Pin Description COM1 and COM2 PortsLCD and Keypad Ethernet Port Interface Module EpimNon-Interactive Mode Non-Interactive Mode ScreensSystem Screen Environment Screen Utilization ScreenSystem Banner Screen Power ScreenInteractive Mode Screens Interactive ModeMain Screen Alarm ScreenENV Power Supply Specific Screen Supplies Installed 2 PWR Redundancy Status 1 on 2 on ExitCommunications Screen Diagnostic Results Screen Diagnostic Module Selection ScreenModule Selection Screen BBU ScreenModule Specific Screen FaultModule Memory Screen Module Environment ScreenEnvironmental Module Specific Screen Module Backplane ScreenEnvironmental Module Environment Screen LCD Contrast Adjustment Screen 9C300-1 Environmental Module Operation Service SafetyWeight DimensionsPhysical EnvironmentalIntroduction Epim SpecificationsParameter Typical Value Worst Worst Case Budget EPIM-F1 and EPIM-F2EPIM-F1 and EPIM-F2 EPIM-F3 Parameter Typical Minimum Maximum Grounding Connector TypePin Number Represents EPIM-A and EPIM-X AUI PortEpim Specifications Connecting a UPS to an EM Uninterruptible Power Supply UPSConfiguring COM Port for UPS Uninterruptible Power Supply UPSMonitoring UPS Verifying ConfigurationUninterruptible Power Supply UPS