Cabletron Systems 9C300-1 manual COM1 and COM2 Ports, Pin Description

Page 19

Out-of-Band Management

COM1 and COM2 Ports

The 9C300-1 Environmental Module front panel has two RJ-45 communication ports for RS-232 serial communication to and from the MMAC-Plus. Figure 3-5illustrates a single RJ-45 communication port connector. COM1 and COM2 can be configured to run the Serial Line Internet Protocol (SLIP), Point-to-Point Protocol (PPP), Local Management via a terminal or modem connection, or monitor an American Power Conversion Smart UPS. Refer to the Local Management Manual for detailed information on configuring the COM1 or COM2 port.

Pin 1

Figure 3-5. RJ-45 Communication Port Connector

Table 3-1details the pinout connections for an RJ-45 communication port connector.

Table 3-6. Pinout Connections RJ-45 Communication Port Connector

Pin

Description

 

 

 

 

1

TRANSMIT

 

 

2

DATA CARRIER DETECT

 

 

3

DATASET READY

 

 

4

RECEIVE

 

 

5

SIGNAL GROUND

 

 

6

DATA TERMINAL READY

 

 

7

REQUEST TO SEND

 

 

8

CLEAR TO SEND

 

 

3-7

Image 19
Contents MMAC-Plus 9C300-1 Environmental Module User’s Guide Page Page DOC Notice FCC NoticeContents Chapter Specifications Appendix B Uninterruptible Power Supply UPSAppendix a Epim Specifications 9C300-1 Environmental Module Using This ManualSystem Cooling FeaturesOut-of-Band Management Hot Swapping Environmental/Power MonitoringRelated Manuals Flash EepromGetting Help Installing the 9C300-1 Environmental Module Installing the 9C300-1 Environmental ModuleInstalling the 9C300-1 Environmental Module Monitoring Functions 9C300-1 Environmental Module OperationTemperature Range LCD Display External Ambient Temperature9C300-1 Environmental Module and Fan Tray Fan Speed Humidity LCD Display Internal Operating Temperature System Humidity System VoltagesLED Color State Description Lanview LEDsOut-of-Band Management Pin Description COM1 and COM2 PortsLCD and Keypad Ethernet Port Interface Module EpimNon-Interactive Mode Screens Non-Interactive ModeSystem Screen Environment Screen Utilization ScreenSystem Banner Screen Power ScreenInteractive Mode Screens Interactive ModeMain Screen Alarm ScreenENV Power Supply Specific Screen Supplies Installed 2 PWR Redundancy Status 1 on 2 on ExitCommunications Screen Diagnostic Results Screen Diagnostic Module Selection ScreenModule Selection Screen BBU ScreenModule Specific Screen FaultModule Memory Screen Module Environment ScreenEnvironmental Module Specific Screen Module Backplane ScreenEnvironmental Module Environment Screen LCD Contrast Adjustment Screen 9C300-1 Environmental Module Operation Service SafetyEnvironmental DimensionsWeight PhysicalIntroduction Epim SpecificationsParameter Typical Value Worst Worst Case Budget EPIM-F1 and EPIM-F2EPIM-F1 and EPIM-F2 EPIM-F3 Parameter Typical Minimum Maximum Grounding Connector TypePin Number Represents EPIM-A and EPIM-X AUI PortEpim Specifications Connecting a UPS to an EM Uninterruptible Power Supply UPSConfiguring COM Port for UPS Uninterruptible Power Supply UPSMonitoring UPS Verifying ConfigurationUninterruptible Power Supply UPS