Extron electronic DVS 304 manual Input aspect ratio, Video mute, EI*X10*EDIDX6

Page 43

Command

ASCII Command

Response

Additional Description

 

(host to scaler)

(scaler to host)

 

 

 

 

 

 

Active pixels

 

 

 

 

Specify a value

12*X7*#

Apx X7* ]

Adjust the active pixels to specified value.

Increment value

+12#

Apx X7* ]

Increase the active pixels.

Decrement value

- 12#

Apx X7* ]

Decrease the active pixels.

View

12#

X7* ]

Show the active pixels.

 

 

 

 

 

Active lines

 

 

 

 

Specify a value

13*X7(#

Aln

X7( ]

Adjust the active lines to specified value.

Increment value

+13#

Aln

X7( ]

Increase the active lines.

Decrement value

- 13#

Aln X7( ]

Decrease the active lines.

View

13#

X7( ]

Show the active lines.

 

 

 

 

Film mode (PAL 2:2 pulldown detection)

 

 

 

Enable

18 * 1#

Flm 1 ]

Enable Film mode (auto sense for 3:2 or

 

 

 

 

2:2 pull down)

Disable

18 * 0#

Flm 0 ]

Disables Film mode (locks de-interlacer to 2:2 pull

 

 

 

 

down).

View

18#

X% ]

View the currently displayed film mode setting.

 

 

 

 

 

Input aspect ratio

 

 

 

 

16:9

9 * 1#

Asp 1]

Set input aspect ratio to 16:9.

4:3

9 * 0#

Asp 0]

Set input aspect ratio to 4:3.

View

9#

X8) ]

View the input aspect ratio (1 = 16:9, 0 = 4:3).

 

 

 

 

 

Video mute

 

 

 

 

Enable mute

1B

Vmt1]

Blank selected input.

Disable mute

0B

Vmt0]

Display selected input.

View

B

X% ]

View the mute status (0 = disabled, 1 = enabled).

EDID emulation (for input 4 — DVI models only)

Save display EDID

ESX10*EDID}

EdidSX10*]

Save display EDID to user space. Only applies where

to user space

 

 

X10* = 2 to 4

Assign EDID to

EA*X10**4EDID}

EdidAX10**4]

Assign EDID to input 4.

input 4

 

 

 

View EDID data

EA*4EDID}

X10*]

 

 

EdidAX10**4]

Export EDID data

EE*X10*EDID}

X6)]

 

 

EdidEX10**X6)]

Import EDID data

EI*X10*EDID}X6)

Edid I*X10*]

View EDID data assignment (input 4). Verbose mode response

Export EDID file data.

Verbose mode response

Import EDID file data to user

Only applies where X10* = 2 to 4.

NOTE: X% = On or off

0 = off/disable, 1 = on/enable

X6)

= EDID file data block

128 bytes of binary data

X7*

= Active pixels

+/- 100 of the default value for video and +/- 512 for RGB

X7( = Active lines

+/- 256 for RGB, +/- 127 for video

X8)

= 0 or 1

0 = 4:3, 1 = 16:9

X10* = EDID resolution and refresh rate

10 to 78 (see table on page 36)

DVS 304 Series • SIS Communication and Control

38

Image 43
Contents DVS 304 Series Vorsicht AchtungPrecaucion AvertissementExtron Electronics. All rights reserved FCC Class a NoticeContents Menu System DVS 304 Series Description IntroductionDVS 304 Models Four inputs FeaturesMemory and input presets DVS 304 DVI ModelsBuffered video outputs Controlling the DVS 304 DevicesOptions and Accessories Rear Panel Cabling CablingVideo PinWiring the RJ-45 No connection Ground Signal ground InputPin RS-232 Function Description InputFront Panel Overview OperationBetween them Menus, Configuration, and AdjustmentsMenu Navigation Using Front Panel Controls Menu OverviewMain Menu Start Auto Image Input ConfigurationInput 4 video type Input 1 video typeInput 2 video type Input 3 video typePicture Control Output ConfigurationOutput Format Resolutions and Refresh RatesSync Polarity Memory Preset Audio Configuration Audio Models OnlyMemory Preset Per input Total Input preset Save Memory PresetClear CLR memory preset Recalling a presetAdvanced Configuration IP ConfigurationAuto-Image Blue modeAuto switch mode RGB delayRefresh Lock Enhance modeOSD label Test patternAuto Memory Per input Total Aspect ModeAuto Memory and Auto Image Features Auto MemoryChanging the input Picture-in-picture modeUsing the swap feature Resetting an InputExit Menu DVS 304 Reset Mode Summary Resetting the UnitMode Activation Result Purpose and Notes Front Panel Lockout Executive Modes System ResetDVS 304 Devices Connected to a Matrix Switcher Setting up the DVS to Work with a Matrix SwitcherFrom the Tools menu, select Sync Scaler to Matrix Switcher Removing the Sync to Matrix Script Sync DVS 304 to Matrix Switcher window opensDVS 304 Series Operation Pin RS-232 Function Description SIS Communication ControlError Numbers Password InformationError Responses Error Response ReferencesUsing the Command and Response Tables Command and ResponsesTelnet Web Browser Symbol Definitions Password is also removed X7@ = Input selection 2 or SIS Command Edid Table see SIS Command and Response Table EI*X10*EDIDX6 Input aspect ratioVideo mute Edid emulation for input 4 DVI models onlyBrightness Color available for PAL and Ntsc onlyTint available for Ntsc composite and S-video only ContrastOutput sync format Zoom modePan Output scaler rateAudio mute audio models only Memory presets inputs 1 toInput presets input 4 only Write and read input preset name inputs 4 presets onlyTest pattern Volume control audio models onlyRGB delay time Auto switch modeView internal temperature PIP modeSwap when PIP mode is On PIP mode audio follow audio model onlySDI field flip Front panel security lockout Executive ModeEnhanced mode Aspect modeFirmware version requests SIS Command and Response Table for IP Control PortEthernet data port E0 *X6 TCEvent control Information requestsEAE X4&SM Web browser specific commandIP setup commands MailECZ E #CZECS E WX1CSECG EMH WX3#CURe-map port designations EMTListing connections EMDFile commands Directory commandsEZI File erase commandsReset ZAP/erase Commands EZAInstalling the Software Signal Processing Products Control ProgramInstallation from the DVD Starting the Sppcp Installation from the Web SiteOrientation Using the SppcpFile menu Sppcp MenusOptions menu Tools menu Sync to Matrix Switcher WindowSystems Settings Window Firmware Loader Window Process Running Help menuControl Tab Window Control TabI/O Configuration Tab Window Configuration TabStatus Bar Advanced Settings TabEthernet Control Accessing the Default Web PagesStatus tab displays the System Status page for the DVS Navigating the Default Web PagesStatus System StatusSystem Settings ConfigurationIP Address Scaler Settings Scaler SettingsPasswords PasswordsFirmware Upgrade Firmware UpgradeWeb Server File Management File ManagementUser Control ControlPresets PresetsMenu System Default Cycle MenuMain Menu Start Auto Image Menu Input Configuration MenuAudio Configuration Menu Output Configuration MenuMemory Preset Menu Advanced Configuration Menu IP Configuration MenuEnable Executive Mode Executive Mode MenuVideo Processing SpecificationsReference Material Video InputAudio DVS 304 A, DVS 304 AD, DVS 304 DVI A, DVS 304 DVI AD SyncControl/Remote Decoder/Scaler General Description Part Number Models Part Numbers and AccessoriesIncluded Parts Optional PartsInstallation of the SDI card Serial Digital Interface SDI Card InstallationDVS 304 Series Reference Information DVS 304 Series Reference Information Europe USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Asia Middle East