IP Address
The DVS 304 IP Address field contains the IP address of the connected scaler. This value is encoded in the flash memory in the scaler.
Valid IP addresses consist of four
The default address is 192.168.254.254, but if this conflicts with other equipment at your installation, you can change the IP address to any valid value.
NOTE: Editing the Extron IP address while connected via the Ethernet port can
immediately disconnect the user from the scaler. Extron recommends editing this field using the
to this screen by assigning an administrator’s password to qualified and knowledgeable personnel only.
Edit this field as follows:
1.Click in the DVS 304 IP address field. The graphic cursor becomes a text cursor.
2.Edit the address as desired.
3.Press the Tab key on the keyboard or click in another field to exit the IP Address field.
4.Click on the Submit button to make the address change take affect.
Gateway IP Address
The Gateway IP Address field identifies the address of the gateway to the mail server to be used if the DVS 304 and the mail server are not on the same subnet.
The gateway IP address has the same validity rules as the system IP address.
Subnet Mask field
The Subnet Mask field is used to determine whether the DVS 304 is on the same subnet as the controlling PC or the mail server when you are subnetting.
Date/Time Settings fields
The Date/Time Settings fields provide a location for viewing and setting the time functions. The adjustable variables are month, day, year, hours, minutes, AM/PM, and (time) zone.
Change the date and time settings as follows:
1.Click the desired variable’s drop box. A drop down scroll box appears.
2.Click the desired value.
NOTE: For quick setting of the date and time, click the Local Date/Time.
Click Cancel at any point before submitting to exit any field changes.
The unit is not updated with those changes The screen refreshes and shows the current device settings.
3.Repeat steps 1 and 2 for all variables that need to be changed.
DVS 304 Series • Ethernet Control | 68 |