Ethernet Control

The DVS 304 features an on-board Web server, displayed as a set of default Web pages. These pages allow you to control and operate the DVS 304 unit through its Ethernet port, connected via a LAN or WAN, using a Web browser such as Microsoft’s Internet Explorer® (version 5.5 or higher).

This section describes these default Web pages, which are always available and cannot be erased or overwritten.

Topics that are covered, include:

Accessing the Default Web Pages

Navigating the Default Web Pages

Accessing the Default Web Pages

Access the DVS 304 through the on-board Web server pages as follows:

1.Double click the Web browser icon on the PC desktop to launch the Web browser.

2.Click in the browser’s Address field.

3.Enter the unit’s IP address in the browser’s Address field.

NOTE: If the local system administrators have not changed the value, the factory-

specified default, 192.168.254.254, is the correct value for this field.

4.If you want the browser to display a page other than the default page (such as a custom page that you have created and uploaded), enter a slash (/) and the file name to open.

NOTE: The browser’s Address field should display the address in the following

format: xxx.xxx.xxx.xxx/{optional_file_name.html}

The following characters are invalid in file names: {space} ~ @ = ‘ [ ] { }

< > ’ “ ; : \ and ?.

5.Press the keyboard Enter key. The DVS 304 checks to see if it is password protected.

If it is not password protected, proceed to step 7. If it is password protected, the DVS 304 downloads the Enter Network Password page.

NOTE: A user name entry is not required.

6.Click in the Password field and type in the appropriate administrator or user password.

DVS 304 Series • Ethernet Control

65

Image 70
Contents DVS 304 Series Avertissement AchtungPrecaucion VorsichtFCC Class a Notice Extron Electronics. All rights reservedContents Menu System DVS 304 Series Description IntroductionDVS 304 Models DVS 304 DVI Models FeaturesMemory and input presets Four inputsControlling the DVS 304 Devices Buffered video outputsOptions and Accessories Cabling Rear Panel CablingPin VideoWiring the RJ-45 Input Ground Signal ground InputPin RS-232 Function Description No connectionOperation Front Panel OverviewMenu Overview Menus, Configuration, and AdjustmentsMenu Navigation Using Front Panel Controls Between themMain Menu Input Configuration Start Auto ImageInput 3 video type Input 1 video typeInput 2 video type Input 4 video typeOutput Configuration Picture ControlOutput Format Resolutions and Refresh RatesSync Polarity Memory Preset Audio Configuration Audio Models OnlyMemory Preset Per input Total Recalling a preset Save Memory PresetClear CLR memory preset Input presetIP Configuration Advanced ConfigurationRGB delay Blue modeAuto switch mode Auto-ImageTest pattern Enhance modeOSD label Refresh LockAuto Memory Aspect ModeAuto Memory and Auto Image Features Auto Memory Per input TotalPicture-in-picture mode Changing the inputUsing the swap feature Resetting an InputExit Menu DVS 304 Reset Mode Summary Resetting the UnitMode Activation Result Purpose and Notes System Reset Front Panel Lockout Executive ModesSetting up the DVS to Work with a Matrix Switcher DVS 304 Devices Connected to a Matrix SwitcherFrom the Tools menu, select Sync Scaler to Matrix Switcher Sync DVS 304 to Matrix Switcher window opens Removing the Sync to Matrix ScriptDVS 304 Series Operation SIS Communication Control Pin RS-232 Function DescriptionError Response References Password InformationError Responses Error NumbersUsing the Command and Response Tables Command and ResponsesTelnet Web Browser Symbol Definitions Password is also removed X7@ = Input selection 2 or SIS Command Edid Table see SIS Command and Response Table Edid emulation for input 4 DVI models only Input aspect ratioVideo mute EI*X10*EDIDX6Contrast Color available for PAL and Ntsc onlyTint available for Ntsc composite and S-video only BrightnessOutput scaler rate Zoom modePan Output sync formatWrite and read input preset name inputs 4 presets only Memory presets inputs 1 toInput presets input 4 only Audio mute audio models onlyAuto switch mode Volume control audio models onlyRGB delay time Test patternPIP mode audio follow audio model only PIP modeSwap when PIP mode is On View internal temperatureAspect mode Front panel security lockout Executive ModeEnhanced mode SDI field flipE0 *X6 TC SIS Command and Response Table for IP Control PortEthernet data port Firmware version requestsEvent control Information requestsEAE Mail Web browser specific commandIP setup commands X4&SM#CZ ECZ EECS E WX1CSECG EMT WX3#CURe-map port designations EMHEMD Listing connectionsDirectory commands File commandsEZA File erase commandsReset ZAP/erase Commands EZIInstalling the Software Signal Processing Products Control ProgramInstallation from the DVD Installation from the Web Site Starting the SppcpUsing the Sppcp OrientationFile menu Sppcp MenusOptions menu Sync to Matrix Switcher Window Tools menuSystems Settings Window Firmware Loader Window Help menu Process Running Control Tab Control Tab WindowConfiguration Tab I/O Configuration Tab WindowAdvanced Settings Tab Status BarAccessing the Default Web Pages Ethernet ControlSystem Status Navigating the Default Web PagesStatus Status tab displays the System Status page for the DVSConfiguration System SettingsIP Address Scaler Settings Scaler SettingsPasswords PasswordsFirmware Upgrade Firmware UpgradeFile Management Web Server File ManagementControl User ControlPresets PresetsMenu System Default Cycle MenuMain Menu Input Configuration Menu Start Auto Image MenuAudio Configuration Menu Output Configuration MenuMemory Preset Menu IP Configuration Menu Advanced Configuration MenuExecutive Mode Menu Enable Executive ModeVideo Input SpecificationsReference Material Video ProcessingAudio DVS 304 A, DVS 304 AD, DVS 304 DVI A, DVS 304 DVI AD SyncControl/Remote Decoder/Scaler General Optional Parts Part Numbers and AccessoriesIncluded Parts Description Part Number ModelsSerial Digital Interface SDI Card Installation Installation of the SDI cardDVS 304 Series Reference Information DVS 304 Series Reference Information Asia Middle East USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Europe