Extron electronic DVS 304 manual Firmware Loader Window

Page 65

To download and install the Firmware Loader application:

1.Go to www.extron.com.

2.Enter “Firmware Loader” in the Search field and press Enter.

3.Locate the Firmware Loader application in the search results and click Download

Now!

4.Follow the on-screen prompts to complete the download.

To update the device’s firmware:

1.From the SPPCP Tools menu, select Update Firmware. The SPPCP minimizes and the Firmware Loader application opens.

NOTE: For full instructions about using the Firmware Loader, click Help > Help (or F1) on the open Firmware Loader window

2.In the Firmware loader window, click File > New Firmware for Selected Devices. A dialog box opens to enable a search for the device-specific firmware file

(with the file extension “.S19”) that has been downloaded to the connected PC.

Figure 33. Firmware Loader Window

3.In the dialog box, browse to the file location. Click on the file then click Open. The dialog box closes, and the file name appears in the Firmware Loader window.

Figure 34. Select Firmware

4.Click Begin. The file uploads to the DVS and the upload progress can be seen on the

Total Progress bar.

DVS 304 Series • SPPCP

60

Image 65
Contents DVS 304 Series Precaucion AchtungAvertissement VorsichtExtron Electronics. All rights reserved FCC Class a NoticeContents Menu System DVS 304 Models IntroductionDVS 304 Series Description Memory and input presets FeaturesDVS 304 DVI Models Four inputsBuffered video outputs Controlling the DVS 304 DevicesOptions and Accessories Rear Panel Cabling CablingVideo PinWiring the RJ-45 Pin RS-232 Function Description Ground Signal ground InputInput No connectionFront Panel Overview OperationMenu Navigation Using Front Panel Controls Menus, Configuration, and AdjustmentsMenu Overview Between themMain Menu Start Auto Image Input ConfigurationInput 2 video type Input 1 video typeInput 3 video type Input 4 video typePicture Control Output ConfigurationSync Polarity Resolutions and Refresh RatesOutput Format Memory Preset Per input Total Audio Configuration Audio Models OnlyMemory Preset Clear CLR memory preset Save Memory PresetRecalling a preset Input presetAdvanced Configuration IP ConfigurationAuto switch mode Blue modeRGB delay Auto-ImageOSD label Enhance modeTest pattern Refresh LockAuto Memory and Auto Image Features Aspect ModeAuto Memory Auto Memory Per input TotalChanging the input Picture-in-picture modeExit Menu Resetting an InputUsing the swap feature Mode Activation Result Purpose and Notes Resetting the UnitDVS 304 Reset Mode Summary Front Panel Lockout Executive Modes System ResetDVS 304 Devices Connected to a Matrix Switcher Setting up the DVS to Work with a Matrix SwitcherFrom the Tools menu, select Sync Scaler to Matrix Switcher Removing the Sync to Matrix Script Sync DVS 304 to Matrix Switcher window opensDVS 304 Series Operation Pin RS-232 Function Description SIS Communication ControlError Responses Password InformationError Response References Error NumbersTelnet Web Browser Command and ResponsesUsing the Command and Response Tables Symbol Definitions Password is also removed X7@ = Input selection 2 or SIS Command Edid Table see SIS Command and Response Table Video mute Input aspect ratioEdid emulation for input 4 DVI models only EI*X10*EDIDX6Tint available for Ntsc composite and S-video only Color available for PAL and Ntsc onlyContrast BrightnessPan Zoom modeOutput scaler rate Output sync formatInput presets input 4 only Memory presets inputs 1 toWrite and read input preset name inputs 4 presets only Audio mute audio models onlyRGB delay time Volume control audio models onlyAuto switch mode Test patternSwap when PIP mode is On PIP modePIP mode audio follow audio model only View internal temperatureEnhanced mode Front panel security lockout Executive ModeAspect mode SDI field flipEthernet data port SIS Command and Response Table for IP Control PortE0 *X6 TC Firmware version requestsEAE Information requestsEvent control IP setup commands Web browser specific commandMail X4&SMECZ E #CZECG WX1CSECS E Re-map port designations WX3#CUEMT EMHListing connections EMDFile commands Directory commandsReset ZAP/erase Commands File erase commandsEZA EZIInstallation from the DVD Signal Processing Products Control ProgramInstalling the Software Starting the Sppcp Installation from the Web SiteOrientation Using the SppcpOptions menu Sppcp MenusFile menu Tools menu Sync to Matrix Switcher WindowSystems Settings Window Firmware Loader Window Process Running Help menuControl Tab Window Control TabI/O Configuration Tab Window Configuration TabStatus Bar Advanced Settings TabEthernet Control Accessing the Default Web PagesStatus Navigating the Default Web PagesSystem Status Status tab displays the System Status page for the DVSSystem Settings ConfigurationIP Address Scaler Settings Scaler SettingsPasswords PasswordsFirmware Upgrade Firmware UpgradeWeb Server File Management File ManagementUser Control ControlPresets PresetsMain Menu Default Cycle MenuMenu System Start Auto Image Menu Input Configuration MenuMemory Preset Menu Output Configuration MenuAudio Configuration Menu Advanced Configuration Menu IP Configuration MenuEnable Executive Mode Executive Mode MenuReference Material SpecificationsVideo Input Video ProcessingControl/Remote Decoder/Scaler SyncAudio DVS 304 A, DVS 304 AD, DVS 304 DVI A, DVS 304 DVI AD General Included Parts Part Numbers and AccessoriesOptional Parts Description Part Number ModelsInstallation of the SDI card Serial Digital Interface SDI Card InstallationDVS 304 Series Reference Information DVS 304 Series Reference Information Europe, Africa, and the Middle China East USA, Canada, South America Japan Central AmericaAsia Middle East Europe