Presets page

The Presets page (located under the Control tab), provides access to memory and input presets, and works in conjunction with the User Control page.

Figure 47. Presets Page

Memory presets

To create a memory preset, do the following:

1.Click the User Control link on the left side of the page. The User Control page appears (figure 46).

2.Click the button for the input (inputs 1, 2, or 3) you would like to preset.

3.Make changes to the attributes (for example, aspect ratio, zoom, brightness, etc.) of your chosen input and press Enter.

4.Click the Presets link on the left side. The Presets page appears (figure 47).

5.Use the drop-down menu to choose preset numbers 1, 2 or 3.

6.Click the Save button.

To return to a preset created after other changes were made, click the Recall button under the preset number. The preset attributes are restored.

Input presets (input 4 only)

To create a input preset, do the following:

1.From the Configuration tab, click the Scaler Setting link at the left side.

2.Select the desired input format for input 4.

3.Click the User Control link on the left side of the page. The User Control page appears (figure 46).

4.Click the button for input 4.

5.Make changes to the picture control settings (for example, aspect ratio, zoom, brightness). You can also create OSD text that is saved as part of the preset. This name can identify the device connected to this input for reference (for example, DVD, VCR).

6.Click the Presets link on the left side. The Presets page appears (figure 47).

7.Use the drop-down menu to choose preset numbers 1 through 128.

8.Click Save. The OSD text you created for the preset appears with the preset number.

To return to a preset created after other changes were made, click the Recall button under the preset name/number. The preset attributes are restored. The OSD text appears on the top left corner for a time specified by the OSD duration setting.

To determine how long the OSD text appears on the screen, click the Scaler Settings link under the Configuration tab and select a duration length.

DVS 304 Series • Ethernet Control

74

Image 79
Contents DVS 304 Series Vorsicht AchtungPrecaucion AvertissementExtron Electronics. All rights reserved FCC Class a NoticeContents Menu System DVS 304 Series Description IntroductionDVS 304 Models Four inputs FeaturesMemory and input presets DVS 304 DVI ModelsBuffered video outputs Controlling the DVS 304 DevicesOptions and Accessories Rear Panel Cabling CablingVideo PinWiring the RJ-45 No connection Ground Signal ground InputPin RS-232 Function Description InputFront Panel Overview OperationBetween them Menus, Configuration, and AdjustmentsMenu Navigation Using Front Panel Controls Menu OverviewMain Menu Start Auto Image Input ConfigurationInput 4 video type Input 1 video typeInput 2 video type Input 3 video typePicture Control Output ConfigurationOutput Format Resolutions and Refresh RatesSync Polarity Memory Preset Audio Configuration Audio Models OnlyMemory Preset Per input Total Input preset Save Memory PresetClear CLR memory preset Recalling a presetAdvanced Configuration IP ConfigurationAuto-Image Blue modeAuto switch mode RGB delayRefresh Lock Enhance modeOSD label Test patternAuto Memory Per input Total Aspect ModeAuto Memory and Auto Image Features Auto MemoryChanging the input Picture-in-picture modeUsing the swap feature Resetting an InputExit Menu DVS 304 Reset Mode Summary Resetting the UnitMode Activation Result Purpose and Notes Front Panel Lockout Executive Modes System ResetDVS 304 Devices Connected to a Matrix Switcher Setting up the DVS to Work with a Matrix SwitcherFrom the Tools menu, select Sync Scaler to Matrix Switcher Removing the Sync to Matrix Script Sync DVS 304 to Matrix Switcher window opensDVS 304 Series Operation Pin RS-232 Function Description SIS Communication ControlError Numbers Password InformationError Responses Error Response ReferencesUsing the Command and Response Tables Command and ResponsesTelnet Web Browser Symbol Definitions Password is also removed X7@ = Input selection 2 or SIS Command Edid Table see SIS Command and Response Table EI*X10*EDIDX6 Input aspect ratioVideo mute Edid emulation for input 4 DVI models onlyBrightness Color available for PAL and Ntsc onlyTint available for Ntsc composite and S-video only ContrastOutput sync format Zoom modePan Output scaler rateAudio mute audio models only Memory presets inputs 1 toInput presets input 4 only Write and read input preset name inputs 4 presets onlyTest pattern Volume control audio models onlyRGB delay time Auto switch modeView internal temperature PIP modeSwap when PIP mode is On PIP mode audio follow audio model onlySDI field flip Front panel security lockout Executive ModeEnhanced mode Aspect modeFirmware version requests SIS Command and Response Table for IP Control PortEthernet data port E0 *X6 TCEvent control Information requestsEAE X4&SM Web browser specific commandIP setup commands MailECZ E #CZECS E WX1CSECG EMH WX3#CURe-map port designations EMTListing connections EMDFile commands Directory commandsEZI File erase commandsReset ZAP/erase Commands EZAInstalling the Software Signal Processing Products Control ProgramInstallation from the DVD Starting the Sppcp Installation from the Web SiteOrientation Using the SppcpFile menu Sppcp MenusOptions menu Tools menu Sync to Matrix Switcher WindowSystems Settings Window Firmware Loader Window Process Running Help menuControl Tab Window Control TabI/O Configuration Tab Window Configuration TabStatus Bar Advanced Settings TabEthernet Control Accessing the Default Web PagesStatus tab displays the System Status page for the DVS Navigating the Default Web PagesStatus System StatusSystem Settings ConfigurationIP Address Scaler Settings Scaler SettingsPasswords PasswordsFirmware Upgrade Firmware UpgradeWeb Server File Management File ManagementUser Control ControlPresets PresetsMenu System Default Cycle MenuMain Menu Start Auto Image Menu Input Configuration MenuAudio Configuration Menu Output Configuration MenuMemory Preset Menu Advanced Configuration Menu IP Configuration MenuEnable Executive Mode Executive Mode MenuVideo Processing SpecificationsReference Material Video InputAudio DVS 304 A, DVS 304 AD, DVS 304 DVI A, DVS 304 DVI AD SyncControl/Remote Decoder/Scaler General Description Part Number Models Part Numbers and AccessoriesIncluded Parts Optional PartsInstallation of the SDI card Serial Digital Interface SDI Card InstallationDVS 304 Series Reference Information DVS 304 Series Reference Information Europe USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Asia Middle East