Extron electronic DVS 304 manual Copyright Information, Password Information, Error Responses

Page 36

Copyright Information

] © Copyright 2010, Extron Electronics, DVS 304 series, Vx.xx Thur, 17 June 2008 11:27:33 ]

The copyright message is displayed upon connecting to IP Link product via TCP/IP or Telnet. Vx.xx is the firmware version number. The current date and time are displayed. This is followed by a Password prompt if a password has been set.

Password Information

The ] Password: prompt requires a password (administrator level or user level) followed by a carriage return. The prompt is repeated if the correct password is not entered.

If correct password is entered, the unit responds with ] Login Administrator ]

or ] Login User ], depending on password entered. If passwords are the same for both administrator and user, the unit defaults to administrator privileges.

Error Responses

When the DVS 304 receives a valid command, it executes the command and sends a response to the host device. If the unit is unable to execute the command because the command contains invalid parameters, it returns an error response to the host.

Error Numbers

E01 — Invalid input number

E10 — Invalid command

E11 — Invalid preset number

E12 — Invalid port number

E13 — Invalid parameter

E14 — Not valid for this configuration

E17 — Invalid command for signal type

E22 — Busy

E24 — Privilege violation

E25 — Device not present

E26 — Maximum number of connections exceeded

E27 — Invalid event number

E28 — Bad filename/file not found

Error Response References

14= Commands that give an E14 (invalid command for this configuration) error if sent to a product whose current configuration does not support the command

24= Commands that give an E24 (privilege violation) error if not administrator level

27= Commands that may give an E27 (invalid event number) error

28= Commands that may give an E28 (file not found) error

DVS 304 Series • SIS Communication and Control

31

Image 36
Contents DVS 304 Series Achtung PrecaucionAvertissement VorsichtFCC Class a Notice Extron Electronics. All rights reservedContents Menu System Introduction DVS 304 Series DescriptionDVS 304 Models Features Memory and input presetsDVS 304 DVI Models Four inputsControlling the DVS 304 Devices Buffered video outputsOptions and Accessories Cabling Rear Panel CablingPin VideoWiring the RJ-45 Ground Signal ground Input Pin RS-232 Function DescriptionInput No connectionOperation Front Panel OverviewMenus, Configuration, and Adjustments Menu Navigation Using Front Panel ControlsMenu Overview Between themMain Menu Input Configuration Start Auto ImageInput 1 video type Input 2 video typeInput 3 video type Input 4 video typeOutput Configuration Picture ControlResolutions and Refresh Rates Output FormatSync Polarity Audio Configuration Audio Models Only Memory PresetMemory Preset Per input Total Save Memory Preset Clear CLR memory presetRecalling a preset Input presetIP Configuration Advanced ConfigurationBlue mode Auto switch modeRGB delay Auto-ImageEnhance mode OSD labelTest pattern Refresh LockAspect Mode Auto Memory and Auto Image FeaturesAuto Memory Auto Memory Per input TotalPicture-in-picture mode Changing the inputResetting an Input Using the swap featureExit Menu Resetting the Unit DVS 304 Reset Mode SummaryMode Activation Result Purpose and Notes System Reset Front Panel Lockout Executive ModesSetting up the DVS to Work with a Matrix Switcher DVS 304 Devices Connected to a Matrix SwitcherFrom the Tools menu, select Sync Scaler to Matrix Switcher Sync DVS 304 to Matrix Switcher window opens Removing the Sync to Matrix ScriptDVS 304 Series Operation SIS Communication Control Pin RS-232 Function DescriptionPassword Information Error ResponsesError Response References Error NumbersCommand and Responses Using the Command and Response TablesTelnet Web Browser Symbol Definitions Password is also removed X7@ = Input selection 2 or SIS Command Edid Table see SIS Command and Response Table Input aspect ratio Video muteEdid emulation for input 4 DVI models only EI*X10*EDIDX6Color available for PAL and Ntsc only Tint available for Ntsc composite and S-video onlyContrast BrightnessZoom mode PanOutput scaler rate Output sync formatMemory presets inputs 1 to Input presets input 4 onlyWrite and read input preset name inputs 4 presets only Audio mute audio models onlyVolume control audio models only RGB delay timeAuto switch mode Test patternPIP mode Swap when PIP mode is OnPIP mode audio follow audio model only View internal temperatureFront panel security lockout Executive Mode Enhanced modeAspect mode SDI field flipSIS Command and Response Table for IP Control Port Ethernet data portE0 *X6 TC Firmware version requestsInformation requests Event controlEAE Web browser specific command IP setup commandsMail X4&SM#CZ ECZ EWX1CS ECS EECG WX3#CU Re-map port designationsEMT EMHEMD Listing connectionsDirectory commands File commandsFile erase commands Reset ZAP/erase CommandsEZA EZISignal Processing Products Control Program Installing the SoftwareInstallation from the DVD Installation from the Web Site Starting the SppcpUsing the Sppcp OrientationSppcp Menus File menuOptions menu Sync to Matrix Switcher Window Tools menuSystems Settings Window Firmware Loader Window Help menu Process RunningControl Tab Control Tab WindowConfiguration Tab I/O Configuration Tab WindowAdvanced Settings Tab Status BarAccessing the Default Web Pages Ethernet ControlNavigating the Default Web Pages StatusSystem Status Status tab displays the System Status page for the DVSConfiguration System SettingsIP Address Scaler Settings Scaler SettingsPasswords PasswordsFirmware Upgrade Firmware UpgradeFile Management Web Server File ManagementControl User ControlPresets PresetsDefault Cycle Menu Menu SystemMain Menu Input Configuration Menu Start Auto Image MenuOutput Configuration Menu Audio Configuration MenuMemory Preset Menu IP Configuration Menu Advanced Configuration MenuExecutive Mode Menu Enable Executive ModeSpecifications Reference MaterialVideo Input Video ProcessingSync Audio DVS 304 A, DVS 304 AD, DVS 304 DVI A, DVS 304 DVI ADControl/Remote Decoder/Scaler General Part Numbers and Accessories Included PartsOptional Parts Description Part Number ModelsSerial Digital Interface SDI Card Installation Installation of the SDI cardDVS 304 Series Reference Information DVS 304 Series Reference Information USA, Canada, South America Japan Central America Europe, Africa, and the Middle China EastAsia Middle East Europe