4.If appropriate, select the Daylight Saving radio button for the DVS’s region, to turn on the daylight saving time feature.

NOTE: When a locations daylight savings time is turned on, the switcher

automatically updates its internal clock between Standard Time and Daylight Savings Time in the spring and fall on the date that the time

change occurs in the country or region selected. When Daylight Savings

Time is turned off, the switcher does not adjust its time reference..

5.Select the Zone variable that is relevant for the DVS’s location

NOTE: The Zone field identifies the standard time zone selected and displays the

amount of time, in hours and minutes, that the local time varies from the

GMT international time reference.

6.Click Submit. The device is updated with the new setting

Scaler Settings page

The Scaler Settings page simulates elements of the DVS 304 menu system, but also allows you to set video input signals (for inputs 2 and 4 only), define output resolutions, and remotely define advanced configurations.

Note that resolutions in the Resolution drop-down menu are linked to refresh rates as shown in the “Resolutions and Refresh Rates” table, page 15, in the “Operation” section.

Figure 42. Scaler Settings Page

DVS 304 Series • Ethernet Control

69

Image 74
Contents DVS 304 Series Avertissement AchtungPrecaucion VorsichtFCC Class a Notice Extron Electronics. All rights reservedContents Menu System DVS 304 Models IntroductionDVS 304 Series Description DVS 304 DVI Models FeaturesMemory and input presets Four inputsControlling the DVS 304 Devices Buffered video outputsOptions and Accessories Cabling Rear Panel CablingPin VideoWiring the RJ-45 Input Ground Signal ground InputPin RS-232 Function Description No connectionOperation Front Panel OverviewMenu Overview Menus, Configuration, and AdjustmentsMenu Navigation Using Front Panel Controls Between themMain Menu Input Configuration Start Auto ImageInput 3 video type Input 1 video typeInput 2 video type Input 4 video typeOutput Configuration Picture ControlSync Polarity Resolutions and Refresh RatesOutput Format Memory Preset Per input Total Audio Configuration Audio Models OnlyMemory Preset Recalling a preset Save Memory PresetClear CLR memory preset Input presetIP Configuration Advanced ConfigurationRGB delay Blue modeAuto switch mode Auto-ImageTest pattern Enhance modeOSD label Refresh LockAuto Memory Aspect ModeAuto Memory and Auto Image Features Auto Memory Per input TotalPicture-in-picture mode Changing the inputExit Menu Resetting an InputUsing the swap feature Mode Activation Result Purpose and Notes Resetting the UnitDVS 304 Reset Mode Summary System Reset Front Panel Lockout Executive ModesSetting up the DVS to Work with a Matrix Switcher DVS 304 Devices Connected to a Matrix SwitcherFrom the Tools menu, select Sync Scaler to Matrix Switcher Sync DVS 304 to Matrix Switcher window opens Removing the Sync to Matrix ScriptDVS 304 Series Operation SIS Communication Control Pin RS-232 Function DescriptionError Response References Password InformationError Responses Error NumbersTelnet Web Browser Command and ResponsesUsing the Command and Response Tables Symbol Definitions Password is also removed X7@ = Input selection 2 or SIS Command Edid Table see SIS Command and Response Table Edid emulation for input 4 DVI models only Input aspect ratioVideo mute EI*X10*EDIDX6Contrast Color available for PAL and Ntsc onlyTint available for Ntsc composite and S-video only BrightnessOutput scaler rate Zoom modePan Output sync formatWrite and read input preset name inputs 4 presets only Memory presets inputs 1 toInput presets input 4 only Audio mute audio models onlyAuto switch mode Volume control audio models onlyRGB delay time Test patternPIP mode audio follow audio model only PIP modeSwap when PIP mode is On View internal temperatureAspect mode Front panel security lockout Executive ModeEnhanced mode SDI field flipE0 *X6 TC SIS Command and Response Table for IP Control PortEthernet data port Firmware version requestsEAE Information requestsEvent control Mail Web browser specific commandIP setup commands X4&SM#CZ ECZ EECG WX1CSECS E EMT WX3#CURe-map port designations EMHEMD Listing connectionsDirectory commands File commandsEZA File erase commandsReset ZAP/erase Commands EZIInstallation from the DVD Signal Processing Products Control ProgramInstalling the Software Installation from the Web Site Starting the SppcpUsing the Sppcp OrientationOptions menu Sppcp MenusFile menu Sync to Matrix Switcher Window Tools menuSystems Settings Window Firmware Loader Window Help menu Process RunningControl Tab Control Tab WindowConfiguration Tab I/O Configuration Tab WindowAdvanced Settings Tab Status BarAccessing the Default Web Pages Ethernet Control System Status Navigating the Default Web Pages Status Status tab displays the System Status page for the DVSConfiguration System SettingsIP Address Scaler Settings Scaler SettingsPasswords PasswordsFirmware Upgrade Firmware UpgradeFile Management Web Server File ManagementControl User ControlPresets PresetsMain Menu Default Cycle MenuMenu System Input Configuration Menu Start Auto Image MenuMemory Preset Menu Output Configuration MenuAudio Configuration Menu IP Configuration Menu Advanced Configuration MenuExecutive Mode Menu Enable Executive ModeVideo Input SpecificationsReference Material Video ProcessingControl/Remote Decoder/Scaler SyncAudio DVS 304 A, DVS 304 AD, DVS 304 DVI A, DVS 304 DVI AD General Optional Parts Part Numbers and AccessoriesIncluded Parts Description Part Number ModelsSerial Digital Interface SDI Card Installation Installation of the SDI cardDVS 304 Series Reference Information DVS 304 Series Reference Information Asia Middle East USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Europe