Extron electronic DVS 304 manual WX1CS, Ecs E, Ecg

Page 54

DVS 304 Series • SIS Communication and Control

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to processor)

(host to processor)

(processor to host)

 

 

 

 

 

 

Set IP address24

E X1$CI }

WX1$CI

Ipi • X1$ ]

X1$ = IP address (xxx.xxx.xxx.xxx).

 

 

 

 

Leading zeros in each of the four fields are

 

 

 

 

optional in setting values.

Read IP address24

ECI }

WCI

X1$]

Leading zeros in each of the four fields are

 

 

 

 

suppressed in returned values.

Read hardware

ECH }

WCH

X1*]

X1* = hardware media access control (MAC)

address (MAC)

 

 

 

address (xx-xx-xx-xx-xx-xx).

Set subnet mask24

E X1(CS}

WX1(CS

Ips•X1( ]

X1( is the subnet mask (xxx.xxx.xxx.xxx).

 

 

 

 

Syntax is the same as for the IP addresses.

 

 

 

 

Leading zeros are optional in setting values.

Read subnet mask

ECS} E

WCS

X1( ]

Leading zeros are suppressed.

Set gateway IP address24

E X1$CG}

W X1$CG

Ipg•X1$ ]

X1$ is the IP address. Leading zeros are

 

 

 

 

optional.

Read gateway IP address

ECG}

WCG

X1$ ]

 

Set broadcast mode

E X6$,X1$EB}

W X6$%2C X1$EB

BmdX6$, X1$ ]

 

Set administrator password 24

E X3#CA}

WX3#CA

Ipa•X3# ]

Set the administrator access password.

 

 

 

 

(X3# is 4-12 alphanumeric characters)

 

 

 

 

The password is case sensitive. Special

 

 

 

 

characters (spaces or symbols) are

 

 

 

 

not allowed.

Clear administrator

E•CA}

W%20CA

Ipa• ]

Clear/remove all passwords (administrator

password 24

 

 

 

and user)

NOTE: A user password cannot be assigned if an administrator password does not exist. Entering a password when the DVS 304 has not been configured yields an E14 response from the processor. If the administrator password is cleared (removed), the user password is also removed.

Read administrator password

ECA}

WCA

X3# ]

NOTE: X% = On/Off 0 = off/disable, 1 = on/enable

X1$

=

IP address (xxx.xxx.xxx.xxx); leading zeros in each of 4 fields are optional in setting values, and are suppressed in returned values.

X1*

=

Hardware (MAC) address (xx-xx-xx-xx-xxxx)

X1( = Subnet mask (xxx.xxx.xxx.xxx). Leading zeros are optional in setting values in each of four fields, and are suppressed in returned values.

X3# = Password (12 characters = maximum length; no special characters are allowed).

X6$ = Broadcast repetition rate in seconds (0 – 255 max; default = 0 = clear). The response is returned with leading zeros. 1 – 11 = entry without password goes to the level

 

 

specified (if an admin password exists). The response as returned as 2-digits with a leading zero.

49

Image 54
Contents DVS 304 Series Avertissement AchtungPrecaucion VorsichtFCC Class a Notice Extron Electronics. All rights reservedContents Menu System Introduction DVS 304 Series DescriptionDVS 304 Models DVS 304 DVI Models FeaturesMemory and input presets Four inputsControlling the DVS 304 Devices Buffered video outputsOptions and Accessories Cabling Rear Panel CablingPin VideoWiring the RJ-45 Input Ground Signal ground InputPin RS-232 Function Description No connectionOperation Front Panel OverviewMenu Overview Menus, Configuration, and AdjustmentsMenu Navigation Using Front Panel Controls Between themMain Menu Input Configuration Start Auto ImageInput 3 video type Input 1 video typeInput 2 video type Input 4 video typeOutput Configuration Picture ControlResolutions and Refresh Rates Output FormatSync Polarity Audio Configuration Audio Models Only Memory PresetMemory Preset Per input Total Recalling a preset Save Memory PresetClear CLR memory preset Input presetIP Configuration Advanced ConfigurationRGB delay Blue modeAuto switch mode Auto-ImageTest pattern Enhance modeOSD label Refresh LockAuto Memory Aspect ModeAuto Memory and Auto Image Features Auto Memory Per input TotalPicture-in-picture mode Changing the inputResetting an Input Using the swap featureExit Menu Resetting the Unit DVS 304 Reset Mode SummaryMode Activation Result Purpose and Notes System Reset Front Panel Lockout Executive ModesSetting up the DVS to Work with a Matrix Switcher DVS 304 Devices Connected to a Matrix SwitcherFrom the Tools menu, select Sync Scaler to Matrix Switcher Sync DVS 304 to Matrix Switcher window opens Removing the Sync to Matrix ScriptDVS 304 Series Operation SIS Communication Control Pin RS-232 Function DescriptionError Response References Password InformationError Responses Error NumbersCommand and Responses Using the Command and Response TablesTelnet Web Browser Symbol Definitions Password is also removed X7@ = Input selection 2 or SIS Command Edid Table see SIS Command and Response Table Edid emulation for input 4 DVI models only Input aspect ratioVideo mute EI*X10*EDIDX6Contrast Color available for PAL and Ntsc onlyTint available for Ntsc composite and S-video only BrightnessOutput scaler rate Zoom modePan Output sync formatWrite and read input preset name inputs 4 presets only Memory presets inputs 1 toInput presets input 4 only Audio mute audio models onlyAuto switch mode Volume control audio models onlyRGB delay time Test patternPIP mode audio follow audio model only PIP modeSwap when PIP mode is On View internal temperatureAspect mode Front panel security lockout Executive ModeEnhanced mode SDI field flipE0 *X6 TC SIS Command and Response Table for IP Control PortEthernet data port Firmware version requests Information requests Event control EAE Mail Web browser specific commandIP setup commands X4&SM#CZ ECZ EWX1CS ECS EECG EMT WX3#CURe-map port designations EMHEMD Listing connectionsDirectory commands File commandsEZA File erase commandsReset ZAP/erase Commands EZISignal Processing Products Control Program Installing the SoftwareInstallation from the DVD Installation from the Web Site Starting the SppcpUsing the Sppcp OrientationSppcp Menus File menuOptions menu Sync to Matrix Switcher Window Tools menuSystems Settings Window Firmware Loader Window Help menu Process RunningControl Tab Control Tab WindowConfiguration Tab I/O Configuration Tab WindowAdvanced Settings Tab Status BarAccessing the Default Web Pages Ethernet ControlSystem Status Navigating the Default Web PagesStatus Status tab displays the System Status page for the DVSConfiguration System SettingsIP Address Scaler Settings Scaler SettingsPasswords PasswordsFirmware Upgrade Firmware UpgradeFile Management Web Server File ManagementControl User ControlPresets PresetsDefault Cycle Menu Menu SystemMain Menu Input Configuration Menu Start Auto Image MenuOutput Configuration Menu Audio Configuration MenuMemory Preset Menu IP Configuration Menu Advanced Configuration MenuExecutive Mode Menu Enable Executive ModeVideo Input SpecificationsReference Material Video ProcessingSync Audio DVS 304 A, DVS 304 AD, DVS 304 DVI A, DVS 304 DVI ADControl/Remote Decoder/Scaler General Optional Parts Part Numbers and AccessoriesIncluded Parts Description Part Number ModelsSerial Digital Interface SDI Card Installation Installation of the SDI cardDVS 304 Series Reference Information DVS 304 Series Reference Information Asia Middle East USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Europe
Related manuals
Manual 96 pages 15.78 Kb