Schneider Electric 890USE19600 Version 1.0 STB NIB 1010 Fieldbus Interface, Summary, Connections

Page 20

The STB NIB 1010 Basic NIM Module

STB NIB 1010 Fieldbus Interface

Summary

The fieldbus interface on the STB NIB 1010 is the point of connection between an

 

Advantys STB island bus and the INTERBUS network. Like every INTERBUS node,

 

the NIM has two nine-pin SUB-D connectors for data reception (in) and transmission

 

(out). The connectors are located on the face of the NIM.

Fieldbus Port

 

The in and out fieldbus interfaces are located on the front of the INTERBUS NIM at

Connections

the top:

It is recommended that you use 9-pin SUB-D connectors compliant with INTERBUS Club or corresponding international standard.

The in connector is optically isolated. The signal level is according to EIA RS-485.

20

890USE19600 April 2004

Image 20
Contents Advantys STB 890USE19600 VersionPage Table of Contents Application Example Important Information Safety InformationProcedure Safety Information About the Book At a GlanceValidity Note Construed as a commitment by Schneider ElectricAbout the Book Topic IntroductionSummary What’s in this Chapter? What Is Advantys STB? IntroductionIsland Bus I/O BasicWhat Is a Network Interface Module? Structural Components of a simplified Interbus network are shown below About InterbusOutputs in 4 ms Physical Layer TopologyNode AddressingInput and output data in the masters buffer On the shift register ring on which data is circulatedIntroduction Product specifications of the basic Interbus NIM STB NIB Basic NIM ModuleWhat’s in this Chapter?External Features of the STB NIB 1010 NIM Features Called out in the illustration belowFeature Function HardwareSpace reserved for the network connectors NIM housing STB NIB 1010 Fieldbus Interface SummaryFieldbus Port ConnectionsConnectors InterbusNetworking CableLED Physical Description OverviewGeneral IndicationsNIM Activity LEDsPower Supply Interface Island is the two-receptacle connector illustrated belowPhysical DescriptionUse either RightLogic Power Improper Galvanic IsolationCharacteristics Power SupplyRequirements ExternalSTB NIB 1010 Module Specifications Technical SpecificationsConfiguring the Island Bus Basic island configuration Auto-AddressingAbout the Island Bus AddressAn Example Module Physical Location Island Bus AddressAbout Auto Auto-ConfigurationConfiguration Been successfully configured at least once RST ButtonHinged cover StageIsland Fallback Scenarios FallbackScenarios HeartbeatFieldbus Communications Support Introduction What’s in this Chapter?Interbus ID Code LowHigh Bytes Data TypeData Length Data Exchange Data and StatusObjects ObjectsInternal Process ImageWord BoundariesOutput Data Input DataExchange Contains the NIM statusApplication Example With an Advantys STB NIB 1010 basic NIMSample Island Assembly AssemblyFieldbus network Sample IslandI/O modules have the following island bus addresses Model Module Type Island Bus AddressNetwork Configuration Considerations For use with an Advantys STB islandConnection Devices on an Interbus networkBefore You BeginSyCon ConsiderationsUsing SyCon to Configure an STB Island on Interbus With SyConStage Description Step Action CommentTo add the NIM to the network configuration ConfiguringAdd the NIM WorkspaceCreate an EDS InstructionsSaving CMD Using CMD to Configure an STB Island on InterbusIsland slave to your configuration using CMD Add AddingIsland Slave DownloadingApplication Example Glossary ARP BOSCan COBComs CRCDhcp DINEDS EIAEMC EMIEOS FedpFsdp GSDBase ScanningIEC IEC type 1 inputIndustrial I/O Input filteringInput polarity Input responseEnergized and open when the coil is energized Energized and closed when the coil is energizedContact NemaNIM NMTPLC PDMPDO Process I/O ProducerConsumer model Profibus DPRTD SAPScada SDOSmmps SnmpTFE StdpTCP UDP VaristorSuppress transient voltage surges Voltage groupIndex Heartbeat message, 34 housing ID code InterbusIndex