Schneider Electric 890USE19600 Version 1.0 manual Heartbeat message, 34 housing ID code, Interbus

Page 70

Index

H

heartbeat message, 34 housing, 19

I

ID code, 36

INTERBUS

bit packing, 39 cables, 21 connectors, 21 data exchange, 38 fieldbus interface, 20, 21 ID code, 36

inputs, 13

last device, 13, 21 network components, 13 network interface, 18 network length, 13 NIM limitations on, 15 node addressing, 15 nodes (maximum), 13 outputs, 13

physical layer, 14 ring, 13, 21 ring topology, 14 standards, 28 transmission media, 14

island bus communications, 11 fallback, 34 LEDs, 23

operational mode, 23, 33 overview, 10, 12 termination, 12

island bus example, 31

island bus sample assembly, 42

L

LED

physical description, 22 LEDs

and COMS states, 23 and reset, 23

BA, 23

ERR, 23 island bus, 23 PWR/UL, 22 RC, 23 RUN, 23 TEST, 23

logic power considerations, 11, 26, 27

integrated power supply, 11, 26, 27 signal, 26

source power supply, 11, 27

N

network connection, 20 network considerations, 11 network interface, 13

NIM

external features, 19 housing, 19

P

parameterization, 32 PDM, 26, 30, 31 physical features, 18

R

RST button

and auto-configuration, 33 caution, 33 functionality, 32, 33 LED indications, 23 physical description, 33

70

Image 70
Contents Advantys STB 890USE19600 VersionPage Table of Contents Application Example Procedure Safety InformationImportant Information Safety Information Validity Note About the BookAt a Glance Construed as a commitment by Schneider ElectricAbout the Book Summary What’s in this Chapter? IntroductionTopic Island Bus I/O What Is Advantys STB?Introduction BasicWhat Is a Network Interface Module? Structural Outputs in 4 ms About InterbusComponents of a simplified Interbus network are shown below Physical Layer TopologyInput and output data in the masters buffer NodeAddressing On the shift register ring on which data is circulatedIntroduction What’s in this Product specifications of the basic Interbus NIMSTB NIB Basic NIM Module Chapter?Feature Function External Features of the STB NIB 1010 NIMFeatures Called out in the illustration below HardwareSpace reserved for the network connectors NIM housing Fieldbus Port STB NIB 1010 Fieldbus InterfaceSummary ConnectionsNetworking ConnectorsInterbus CableGeneral LED Physical DescriptionOverview IndicationsNIM Activity LEDsPhysical Power Supply InterfaceIsland is the two-receptacle connector illustrated below DescriptionUse either RightLogic Power Improper Galvanic IsolationRequirements CharacteristicsPower Supply ExternalSTB NIB 1010 Module Specifications Technical SpecificationsConfiguring the Island Bus About the Island Basic island configurationAuto-Addressing Bus AddressAn Example Module Physical Location Island Bus AddressConfiguration Auto-ConfigurationAbout Auto Hinged cover Been successfully configured at least onceRST Button StageScenarios Island Fallback ScenariosFallback HeartbeatFieldbus Communications Support Introduction What’s in this Chapter?High Bytes Interbus ID CodeLow Data TypeData Length Objects Data ExchangeData and Status ObjectsWord InternalProcess Image BoundariesExchange Output DataInput Data Contains the NIM statusApplication Example With an Advantys STB NIB 1010 basic NIMFieldbus network Sample Island AssemblyAssembly Sample IslandI/O modules have the following island bus addresses Model Module Type Island Bus AddressConnection Network Configuration ConsiderationsFor use with an Advantys STB island Devices on an Interbus networkSyCon Before YouBegin ConsiderationsStage Description Using SyCon to Configure an STB Island on InterbusWith SyCon Step Action CommentAdd the NIM To add the NIM to the network configurationConfiguring WorkspaceCreate an EDS InstructionsSaving Island slave to your configuration using CMD Using CMD to Configure an STB Island on InterbusCMD Island Slave AddAdding DownloadingApplication Example Glossary ARP BOSComs CanCOB CRCEDS DhcpDIN EIAEOS EMCEMI FedpFsdp GSDIEC BaseScanning IEC type 1 inputInput polarity Industrial I/OInput filtering Input responseContact Energized and open when the coil is energizedEnergized and closed when the coil is energized NemaNIM NMTPDO PDMPLC Consumer model Process I/OProducer Profibus DPScada RTDSAP SDOSmmps SnmpTCP StdpTFE Suppress transient voltage surges UDPVaristor Voltage groupIndex Heartbeat message, 34 housing ID code InterbusIndex