D

DeviceNet

DeviceNet is a low-level, connection-based network that is based on CAN, a serial

protocol

bus system without a defined application layer. DeviceNet, therefore, defines a layer

 

for the industrial application of CAN.

DHCP

dynamic host configuration protocol. A TCP/IP protocol that allows a server to

 

assign an IP address based on a role name (host name) to a network node.

differential input A type of input design where two wires (+ and -) are run from each signal source to the data acquisition interface. The voltage between the input and the interface ground are measured by two high-impedance amplifiers, and the outputs from the two amplifiers are subtracted by a third amplifier to yield the difference between the

+and - inputs. Voltage common to both wires is thereby removed. Differential design solves the problem of ground differences found in single-ended connections, and it also reduces the cross-channel noise problem.

digital I/O

An input or output that has an individual circuit connection at the module

 

corresponding directly to a data table bit or word that stores the value of the signal

 

at that I/O circuit. It allows the control logic to have discrete access to the I/O values.

DIN

Deutsche industrial norms. A German agency that sets engineering and

 

dimensional standards and now has worldwide recognition.

 

 

E

economy

A special type of STB I/O segment created when an STB NCO 1113 economy

segment

CANopen NIM is used in the first location. In this implementation, the NIM acts as a

 

simple gateway between the I/O modules in the segment and a CANopen master.

 

Each I/O module in an economy segment acts as a independent node on the

 

CANopen network. An economy segment cannot be extended to other STB I/O

 

segments, preferred modules or standard CANopen devices.

EDS

electronic data sheet. The EDS is a standardized ASCII file that contains information

 

about a network device’s communications functionality and the contents of its object

 

dictionary. The EDS also defines device-specific and manufacturer-specific objects.

EIA

Electronic Industries Association. An organization that establishes electrical/

 

electronic and data communication standards.

56

890USE19600 April 2004

Image 56
Contents Advantys STB 890USE19600 VersionPage Table of Contents Application Example Important Information Safety InformationProcedure Safety Information About the Book At a GlanceValidity Note Construed as a commitment by Schneider ElectricAbout the Book Topic IntroductionSummary What’s in this Chapter? What Is Advantys STB? IntroductionIsland Bus I/O BasicWhat Is a Network Interface Module? Structural Components of a simplified Interbus network are shown below About InterbusOutputs in 4 ms Physical Layer TopologyNode AddressingInput and output data in the masters buffer On the shift register ring on which data is circulatedIntroduction Product specifications of the basic Interbus NIM STB NIB Basic NIM ModuleWhat’s in this Chapter?External Features of the STB NIB 1010 NIM Features Called out in the illustration belowFeature Function HardwareSpace reserved for the network connectors NIM housing STB NIB 1010 Fieldbus Interface SummaryFieldbus Port ConnectionsConnectors InterbusNetworking CableLED Physical Description OverviewGeneral IndicationsNIM Activity LEDsPower Supply Interface Island is the two-receptacle connector illustrated belowPhysical DescriptionUse either RightLogic Power Improper Galvanic IsolationCharacteristics Power SupplyRequirements ExternalSTB NIB 1010 Module Specifications Technical SpecificationsConfiguring the Island Bus Basic island configuration Auto-AddressingAbout the Island Bus AddressAn Example Module Physical Location Island Bus AddressAbout Auto Auto-ConfigurationConfiguration Been successfully configured at least once RST ButtonHinged cover StageIsland Fallback Scenarios FallbackScenarios HeartbeatFieldbus Communications Support Introduction What’s in this Chapter?Interbus ID Code LowHigh Bytes Data TypeData Length Data Exchange Data and StatusObjects ObjectsInternal Process ImageWord BoundariesOutput Data Input DataExchange Contains the NIM statusApplication Example With an Advantys STB NIB 1010 basic NIMSample Island Assembly AssemblyFieldbus network Sample IslandI/O modules have the following island bus addresses Model Module Type Island Bus AddressNetwork Configuration Considerations For use with an Advantys STB islandConnection Devices on an Interbus networkBefore You BeginSyCon ConsiderationsUsing SyCon to Configure an STB Island on Interbus With SyConStage Description Step Action CommentTo add the NIM to the network configuration ConfiguringAdd the NIM WorkspaceCreate an EDS InstructionsSaving CMD Using CMD to Configure an STB Island on InterbusIsland slave to your configuration using CMD Add AddingIsland Slave DownloadingApplication Example Glossary ARP BOSCan COBComs CRCDhcp DINEDS EIAEMC EMIEOS FedpFsdp GSDBase ScanningIEC IEC type 1 inputIndustrial I/O Input filteringInput polarity Input responseEnergized and open when the coil is energized Energized and closed when the coil is energizedContact NemaNIM NMTPLC PDMPDO Process I/O ProducerConsumer model Profibus DPRTD SAPScada SDOSmmps SnmpTFE StdpTCP UDP VaristorSuppress transient voltage surges Voltage groupIndex Heartbeat message, 34 housing ID code InterbusIndex