Schneider Electric 890USE19600 Version 1.0, INTERBUS Basic Network Interface Module Structural

Page 12

Introduction

Structural

The following figure illustrates the multiple roles of the NIM. The figure provides a

Overview

network view and a physical representation of the island bus:

1fieldbus master

2external 24 VDC power supply, the source for logic power on the island

3power distribution module (PDM)

4island node

5island bus terminator plate

6other nodes on the fieldbus network

7fieldbus network terminator (if required)

12

890USE19600 April 2004

Image 12
Contents Advantys STB 890USE19600 VersionPage Table of Contents Application Example Safety Information ProcedureImportant Information Safety Information About the Book At a GlanceValidity Note Construed as a commitment by Schneider ElectricAbout the Book Introduction Summary What’s in this Chapter?Topic What Is Advantys STB? IntroductionIsland Bus I/O BasicWhat Is a Network Interface Module? Structural About Interbus Outputs in 4 msComponents of a simplified Interbus network are shown below Physical Layer TopologyNode AddressingInput and output data in the masters buffer On the shift register ring on which data is circulatedIntroduction Product specifications of the basic Interbus NIM STB NIB Basic NIM ModuleWhat’s in this Chapter?External Features of the STB NIB 1010 NIM Features Called out in the illustration belowFeature Function HardwareSpace reserved for the network connectors NIM housing STB NIB 1010 Fieldbus Interface SummaryFieldbus Port ConnectionsConnectors InterbusNetworking CableLED Physical Description OverviewGeneral IndicationsNIM Activity LEDsPower Supply Interface Island is the two-receptacle connector illustrated belowPhysical DescriptionUse either RightLogic Power Improper Galvanic IsolationCharacteristics Power SupplyRequirements ExternalSTB NIB 1010 Module Specifications Technical SpecificationsConfiguring the Island Bus Basic island configuration Auto-AddressingAbout the Island Bus AddressAn Example Module Physical Location Island Bus AddressAuto-Configuration ConfigurationAbout Auto Been successfully configured at least once RST ButtonHinged cover StageIsland Fallback Scenarios FallbackScenarios HeartbeatFieldbus Communications Support Introduction What’s in this Chapter?Interbus ID Code LowHigh Bytes Data TypeData Length Data Exchange Data and StatusObjects ObjectsInternal Process ImageWord BoundariesOutput Data Input DataExchange Contains the NIM statusApplication Example With an Advantys STB NIB 1010 basic NIMSample Island Assembly AssemblyFieldbus network Sample IslandI/O modules have the following island bus addresses Model Module Type Island Bus AddressNetwork Configuration Considerations For use with an Advantys STB islandConnection Devices on an Interbus networkBefore You BeginSyCon ConsiderationsUsing SyCon to Configure an STB Island on Interbus With SyConStage Description Step Action CommentTo add the NIM to the network configuration ConfiguringAdd the NIM WorkspaceCreate an EDS InstructionsSaving Using CMD to Configure an STB Island on Interbus Island slave to your configuration using CMDCMD Add AddingIsland Slave DownloadingApplication Example Glossary ARP BOSCan COBComs CRCDhcp DINEDS EIAEMC EMIEOS FedpFsdp GSDBase ScanningIEC IEC type 1 inputIndustrial I/O Input filteringInput polarity Input responseEnergized and open when the coil is energized Energized and closed when the coil is energizedContact NemaNIM NMTPDM PDOPLC Process I/O ProducerConsumer model Profibus DPRTD SAPScada SDOSmmps SnmpStdp TCPTFE UDP VaristorSuppress transient voltage surges Voltage groupIndex Heartbeat message, 34 housing ID code InterbusIndex