Schneider Electric 890USE19600 Version 1.0 manual LED Physical Description, Overview, General

Page 22

The STB NIB 1010 Basic NIM Module

LED Physical Description

Overview

The six LEDs implemented in the STB NIB 1010 INTERBUS NIM are visual

 

indications of the operating status of the island bus on an INTERBUS network. The

 

LED array is located at the top of the NIM front bezel.

General

The bottom three LEDs indicate the status of data exchange between the

Indications

INTERBUS fieldbus master and the Advantys island bus:

 

LED 4—RC (remote bus check)

 

LED 5—BA (bus active)

 

LED 6—RD (remote bus disabled)

 

The top three LEDs indicate activity or events on the NIM:

 

LED 1—RUN

 

LED 2—PWR/UL

 

LED 3—ERR

 

The following tables describe the LED behavior in more detail. When you refer to

 

these tables, keep in mind:

 

It is assumed that the PWR/UL LED is on continuously, indicating that the NIM is

 

receiving adequate power. If the PWR/UL LED is off, logic power to the NIM is off

 

￿or insufficient.

 

Individual blinks are approximately 200 ms. There is a 1-second interval between

 

blink sequences. For example:

 

blinking—blinks steadily, alternating between 200 ms on and 200 ms off

 

blink 1—blinks once (200 ms), then 1 second off

 

￿blink 2—blinks twice (200 ms on, 200 ms off, 200 ms on), then 1 second off

 

blink n—blinks n (some number) times, then 1 second off

 

 

22

890USE19600 April 2004

Image 22
Contents Advantys STB 890USE19600 VersionPage Table of Contents Application Example Procedure Safety InformationImportant Information Safety Information Validity Note About the BookAt a Glance Construed as a commitment by Schneider ElectricAbout the Book Summary What’s in this Chapter? IntroductionTopic Island Bus I/O What Is Advantys STB?Introduction BasicWhat Is a Network Interface Module? Structural Outputs in 4 ms About InterbusComponents of a simplified Interbus network are shown below Physical Layer TopologyInput and output data in the masters buffer NodeAddressing On the shift register ring on which data is circulatedIntroduction What’s in this Product specifications of the basic Interbus NIMSTB NIB Basic NIM Module Chapter?Feature Function External Features of the STB NIB 1010 NIMFeatures Called out in the illustration below HardwareSpace reserved for the network connectors NIM housing Fieldbus Port STB NIB 1010 Fieldbus InterfaceSummary ConnectionsNetworking ConnectorsInterbus CableGeneral LED Physical DescriptionOverview IndicationsNIM Activity LEDsPhysical Power Supply InterfaceIsland is the two-receptacle connector illustrated below DescriptionUse either RightLogic Power Improper Galvanic IsolationRequirements CharacteristicsPower Supply ExternalSTB NIB 1010 Module Specifications Technical SpecificationsConfiguring the Island Bus About the Island Basic island configurationAuto-Addressing Bus AddressAn Example Module Physical Location Island Bus AddressConfiguration Auto-ConfigurationAbout Auto Hinged cover Been successfully configured at least onceRST Button StageScenarios Island Fallback ScenariosFallback HeartbeatFieldbus Communications Support Introduction What’s in this Chapter?High Bytes Interbus ID CodeLow Data TypeData Length Objects Data ExchangeData and Status ObjectsWord InternalProcess Image BoundariesExchange Output DataInput Data Contains the NIM statusApplication Example With an Advantys STB NIB 1010 basic NIMFieldbus network Sample Island AssemblyAssembly Sample IslandI/O modules have the following island bus addresses Model Module Type Island Bus AddressConnection Network Configuration ConsiderationsFor use with an Advantys STB island Devices on an Interbus networkSyCon Before YouBegin ConsiderationsStage Description Using SyCon to Configure an STB Island on InterbusWith SyCon Step Action CommentAdd the NIM To add the NIM to the network configurationConfiguring WorkspaceCreate an EDS InstructionsSaving Island slave to your configuration using CMD Using CMD to Configure an STB Island on InterbusCMD Island Slave AddAdding DownloadingApplication Example Glossary ARP BOSComs CanCOB CRCEDS DhcpDIN EIAEOS EMCEMI FedpFsdp GSDIEC BaseScanning IEC type 1 inputInput polarity Industrial I/OInput filtering Input responseContact Energized and open when the coil is energizedEnergized and closed when the coil is energized NemaNIM NMTPDO PDMPLC Consumer model Process I/OProducer Profibus DPScada RTDSAP SDOSmmps SnmpTCP StdpTFE Suppress transient voltage surges UDPVaristor Voltage groupIndex Heartbeat message, 34 housing ID code InterbusIndex