Glossary

 

 

RTD

resistive temperature detect. An RTD device is a temperature transducer composed

 

of conductive wire elements typically made of platinum, nickel, copper, or nickel-

 

iron. An RTD device provides a variable resistance across a specified temperature

 

range.

Rx

reception. For example, in a CAN-based network, a PDO is described as an RxPDO

 

of the device that receives it.

 

 

S

SAP

service access point. The point at which the services of one communications layer,

 

as defined by the ISO OSI reference model, is made available to the next layer.

SCADA

supervisory control and data acquisition. Typically accomplished in industrial

 

settings by means of microcomputers.

SDO

service data object. In CAN-based networks, SDO messages are used by the

 

fieldbus master to access (read/write) the object directories of network nodes.

segment

A group of interconnected I/O and power modules on an island bus. An island must

 

have at least one segment and, depending on the type of NIM used, may have as

 

many as seven segments. The first (leftmost) module in a segment needs to provide

 

logic power and island bus communications to the I/O modules on its right. In the

 

primary or basic segment, that function is filled by a NIM. In an extension segment,

 

that function is filled by an STB XBE 1200 BOS module. (An island running with a

 

basic NIM does not support extension segments.)

SELV

safety extra low voltage. A secondary circuit designed and protected so that the

 

voltage between any two accessible parts (or between one accessible part and the

 

PE terminal for Class 1 equipment) does not exceed a specified value under normal

 

conditions or under single-fault conditions.

SIM

subscriber identification module. Originally intended for authenticating users of

 

mobile communications, SIMs now have multiple applications. In Advantys STB,

 

configuration data created or modified with the Advantys configuration software can

 

be stored on a SIM and then written to the NIM’s Flash memory.

single-ended

An analog input design technique whereby a wire from each signal source is

inputs

connected to the data acquisition interface, and the difference between the signal

 

and ground is measured. Two conditions are imperative to the success of this design

 

technique—the signal source must be grounded, and the signal ground and data

 

acquisition interface ground (the PDM lead) must have the same potential.

890USE19600 April 2004

65

Image 65
Contents 890USE19600 Version Advantys STBPage Table of Contents Application Example Important Information Safety InformationProcedure Safety Information At a Glance About the BookValidity Note Construed as a commitment by Schneider ElectricAbout the Book Topic IntroductionSummary What’s in this Chapter? Introduction What Is Advantys STB?Island Bus I/O BasicWhat Is a Network Interface Module? Structural Components of a simplified Interbus network are shown below About InterbusOutputs in 4 ms Topology Physical LayerAddressing NodeInput and output data in the masters buffer On the shift register ring on which data is circulatedIntroduction STB NIB Basic NIM Module Product specifications of the basic Interbus NIMWhat’s in this Chapter?Features Called out in the illustration below External Features of the STB NIB 1010 NIMFeature Function HardwareSpace reserved for the network connectors NIM housing Summary STB NIB 1010 Fieldbus InterfaceFieldbus Port ConnectionsInterbus ConnectorsNetworking CableOverview LED Physical DescriptionGeneral IndicationsLEDs NIM ActivityIsland is the two-receptacle connector illustrated below Power Supply InterfacePhysical DescriptionRight Use eitherImproper Galvanic Isolation Logic PowerPower Supply CharacteristicsRequirements ExternalTechnical Specifications STB NIB 1010 Module SpecificationsConfiguring the Island Bus Auto-Addressing Basic island configurationAbout the Island Bus AddressModule Physical Location Island Bus Address An ExampleAbout Auto Auto-ConfigurationConfiguration RST Button Been successfully configured at least onceHinged cover StageFallback Island Fallback ScenariosScenarios HeartbeatIntroduction What’s in this Chapter? Fieldbus Communications SupportLow Interbus ID CodeHigh Bytes Data TypeData Length Data and Status Data ExchangeObjects ObjectsProcess Image InternalWord BoundariesInput Data Output DataExchange Contains the NIM statusWith an Advantys STB NIB 1010 basic NIM Application ExampleAssembly Sample Island AssemblyFieldbus network Sample IslandModel Module Type Island Bus Address I/O modules have the following island bus addressesFor use with an Advantys STB island Network Configuration ConsiderationsConnection Devices on an Interbus networkBegin Before YouSyCon ConsiderationsWith SyCon Using SyCon to Configure an STB Island on InterbusStage Description Step Action CommentConfiguring To add the NIM to the network configurationAdd the NIM WorkspaceInstructions Create an EDSSaving CMD Using CMD to Configure an STB Island on InterbusIsland slave to your configuration using CMD Adding AddIsland Slave DownloadingApplication Example Glossary BOS ARPCOB CanComs CRCDIN DhcpEDS EIAEMI EMCEOS FedpGSD FsdpScanning BaseIEC IEC type 1 inputInput filtering Industrial I/OInput polarity Input responseEnergized and closed when the coil is energized Energized and open when the coil is energizedContact NemaNMT NIMPLC PDMPDO Producer Process I/OConsumer model Profibus DPSAP RTDScada SDOSnmp SmmpsTFE StdpTCP Varistor UDPSuppress transient voltage surges Voltage groupIndex Interbus Heartbeat message, 34 housing ID codeIndex