Glossary

 

 

EMC

electromagnetic compatibility. Devices that meet EMC requirements can operate

 

within a system’s expected electromagnetic limits without error.

EMI

electromagnetic interference. EMI can cause an interruption, malfunction, or

 

disturbance in the performance of electronic equipment. It occurs when a source

 

electronically transmits a signal that interferes with other equipment.

EOS

end of segment. When more than one segment of I/O modules is used in an island,

 

an STB XBE 1000 EOS module is installed in the last position in every segment that

 

has an extension following it. The EOS module extends island bus communications

 

to the next segment.

Ethernet

A LAN cabling and signaling specification used to connect devices within a defined

 

area, e.g., a building. Ethernet uses a bus or a star topology to connect different

 

nodes on a network.0

Ethernet II

A frame format in which the header specifies the packet type, Ethernet II is the

 

default frame format for STB NIP 2212 communications.

 

 

F

fallback state

A safe state to which an Advantys STB I/O module can return in the event that its

 

communication connection fails.

fallback value

The value that a device assumes during fallback. Typically, the fallback value is

 

either configurable or the last stored value for the device.

FED_P

Fipio extended device profile. On a Fipio network, the standard device profile type

 

for agents whose data length is more than eight words and equal to or less than

 

thirty-two words.

Fipio

Fieldbus Interface Protocol (FIP). An open fieldbus standard and protocol that

 

conforms to the FIP/World FIP standard. Fipio is designed to provide low-level

 

configuration, parameterization, data exchange, and diagnostic services.

Flash memory

Flash memory is nonvolatile memory that can be overwritten. It is stored on a special

 

EEPROM that can be erased and reprogrammed.

FRD_P

Fipio reduced device profile. On a Fipio network, the standard device profile type for

 

agents whose data length is two words or less.

890USE19600 April 2004

57

Image 57
Contents 890USE19600 Version Advantys STBPage Table of Contents Application Example Safety Information ProcedureImportant Information Safety Information At a Glance About the BookValidity Note Construed as a commitment by Schneider ElectricAbout the Book Introduction Summary What’s in this Chapter?Topic Introduction What Is Advantys STB?Island Bus I/O BasicWhat Is a Network Interface Module? Structural About Interbus Outputs in 4 msComponents of a simplified Interbus network are shown below Topology Physical LayerAddressing NodeInput and output data in the masters buffer On the shift register ring on which data is circulatedIntroduction STB NIB Basic NIM Module Product specifications of the basic Interbus NIMWhat’s in this Chapter?Features Called out in the illustration below External Features of the STB NIB 1010 NIMFeature Function HardwareSpace reserved for the network connectors NIM housing Summary STB NIB 1010 Fieldbus InterfaceFieldbus Port ConnectionsInterbus ConnectorsNetworking CableOverview LED Physical DescriptionGeneral IndicationsLEDs NIM ActivityIsland is the two-receptacle connector illustrated below Power Supply InterfacePhysical DescriptionRight Use eitherImproper Galvanic Isolation Logic PowerPower Supply CharacteristicsRequirements ExternalTechnical Specifications STB NIB 1010 Module SpecificationsConfiguring the Island Bus Auto-Addressing Basic island configurationAbout the Island Bus AddressModule Physical Location Island Bus Address An ExampleAuto-Configuration ConfigurationAbout Auto RST Button Been successfully configured at least onceHinged cover StageFallback Island Fallback ScenariosScenarios HeartbeatIntroduction What’s in this Chapter? Fieldbus Communications SupportLow Interbus ID CodeHigh Bytes Data TypeData Length Data and Status Data ExchangeObjects ObjectsProcess Image InternalWord BoundariesInput Data Output DataExchange Contains the NIM statusWith an Advantys STB NIB 1010 basic NIM Application ExampleAssembly Sample Island AssemblyFieldbus network Sample IslandModel Module Type Island Bus Address I/O modules have the following island bus addressesFor use with an Advantys STB island Network Configuration ConsiderationsConnection Devices on an Interbus networkBegin Before YouSyCon ConsiderationsWith SyCon Using SyCon to Configure an STB Island on InterbusStage Description Step Action CommentConfiguring To add the NIM to the network configurationAdd the NIM WorkspaceInstructions Create an EDSSaving Using CMD to Configure an STB Island on Interbus Island slave to your configuration using CMDCMD Adding AddIsland Slave DownloadingApplication Example Glossary BOS ARPCOB CanComs CRCDIN DhcpEDS EIAEMI EMCEOS FedpGSD FsdpScanning BaseIEC IEC type 1 inputInput filtering Industrial I/OInput polarity Input responseEnergized and closed when the coil is energized Energized and open when the coil is energizedContact NemaNMT NIMPDM PDOPLC Producer Process I/OConsumer model Profibus DPSAP RTDScada SDOSnmp SmmpsStdp TCPTFE Varistor UDPSuppress transient voltage surges Voltage groupIndex Interbus Heartbeat message, 34 housing ID codeIndex