Glossary

ARP

address resolution protocol. The IP network layer protocol, which uses ARP to map

 

an IP address to a MAC (hardware) address.

auto baud

The automatic assignment and detection of a common baud rate as well as the

 

ability of a device on a network to adapt to that rate.

auto-addressing

The assignment of an address to each island bus I/O module and preferred device.

auto-

The ability of island modules to operate with predefined default parameters. A

configuration

configuration of the island bus based completely on the actual assembly of I/O

 

modules.

 

 

B

basic I/O

Low-cost Advantys STB input/output modules that use a fixed set of operating

 

parameters. A basic I/O module cannot be reconfigured with the Advantys

 

configuration software and cannot be used in reflex actions.

basic network

A low-cost Advantys STB network interface module that supports a single segment

interface

of up to 12 Advantys STB I/O modules. A basic NIM does not support the Advantys

 

configuration software, reflex actions, island bus extensions, nor the use of an HMI

 

panel.

basic power

A low-cost Advantys STB PDM that distributes sensor power and actuator power

distribution

over a single field power bus on the island. The bus provides a maximum of 4 A total

module

power. A basic PDM requires one 5 A fuse to protect the I/O.

BootP

bootstrap protocol. A UDP/IP protocol that allows an internet node to obtain its IP

 

parameters based on its MAC address.

BOS

beginning of segment. When more than one segment of I/O modules is used in an

 

island, an STB XBE 1200 BOS module is installed in the first position in each

 

extension segment. Its job is to carry island bus communications to and generate

 

logic power for the modules in the extension segment.

bus arbitrator

A master on a Fipio network.

 

 

54

890USE19600 April 2004

Image 54
Contents Advantys STB 890USE19600 VersionPage Table of Contents Application Example Safety Information ProcedureImportant Information Safety Information Validity Note About the BookAt a Glance Construed as a commitment by Schneider ElectricAbout the Book Introduction Summary What’s in this Chapter?Topic Island Bus I/O What Is Advantys STB?Introduction BasicWhat Is a Network Interface Module? Structural About Interbus Outputs in 4 msComponents of a simplified Interbus network are shown below Physical Layer TopologyInput and output data in the masters buffer NodeAddressing On the shift register ring on which data is circulatedIntroduction What’s in this Product specifications of the basic Interbus NIMSTB NIB Basic NIM Module Chapter?Feature Function External Features of the STB NIB 1010 NIMFeatures Called out in the illustration below HardwareSpace reserved for the network connectors NIM housing Fieldbus Port STB NIB 1010 Fieldbus InterfaceSummary ConnectionsNetworking ConnectorsInterbus CableGeneral LED Physical DescriptionOverview IndicationsNIM Activity LEDsPhysical Power Supply InterfaceIsland is the two-receptacle connector illustrated below DescriptionUse either RightLogic Power Improper Galvanic IsolationRequirements CharacteristicsPower Supply ExternalSTB NIB 1010 Module Specifications Technical SpecificationsConfiguring the Island Bus About the Island Basic island configurationAuto-Addressing Bus AddressAn Example Module Physical Location Island Bus AddressAuto-Configuration ConfigurationAbout Auto Hinged cover Been successfully configured at least onceRST Button StageScenarios Island Fallback ScenariosFallback HeartbeatFieldbus Communications Support Introduction What’s in this Chapter?High Bytes Interbus ID CodeLow Data TypeData Length Objects Data ExchangeData and Status ObjectsWord InternalProcess Image BoundariesExchange Output DataInput Data Contains the NIM statusApplication Example With an Advantys STB NIB 1010 basic NIMFieldbus network Sample Island AssemblyAssembly Sample IslandI/O modules have the following island bus addresses Model Module Type Island Bus AddressConnection Network Configuration ConsiderationsFor use with an Advantys STB island Devices on an Interbus networkSyCon Before YouBegin ConsiderationsStage Description Using SyCon to Configure an STB Island on InterbusWith SyCon Step Action CommentAdd the NIM To add the NIM to the network configurationConfiguring WorkspaceCreate an EDS InstructionsSaving Using CMD to Configure an STB Island on Interbus Island slave to your configuration using CMDCMD Island Slave AddAdding DownloadingApplication Example Glossary ARP BOSComs CanCOB CRCEDS DhcpDIN EIAEOS EMCEMI FedpFsdp GSDIEC BaseScanning IEC type 1 inputInput polarity Industrial I/OInput filtering Input responseContact Energized and open when the coil is energizedEnergized and closed when the coil is energized NemaNIM NMTPDM PDOPLC Consumer model Process I/OProducer Profibus DPScada RTDSAP SDOSmmps SnmpStdp TCPTFE Suppress transient voltage surges UDPVaristor Voltage groupIndex Heartbeat message, 34 housing ID code InterbusIndex