Schneider Electric INTERBUS Basic Network Interface Module manual Table of Contents

Page 3

Table of Contents

Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

About the Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Chapter 1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

What Is Advantys STB? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

What Is a Network Interface Module? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

About INTERBUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Chapter 2 The STB NIB 1010 Basic NIM Module . . . . . . . . . . . . . . . . . . . . 17

External Features of the STB NIB 1010 NIM . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 STB NIB 1010 Fieldbus Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 LED Physical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Power Supply Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Logic Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Selecting a Source Power Supply for the Island’s Logic Power Bus. . . . . . . . . . 27 STB NIB 1010 Module Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Chapter 3 Configuring the Island Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Auto-Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Auto-Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

The RST Button. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Island Fallback Scenarios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Chapter 4 Fieldbus Communications Support . . . . . . . . . . . . . . . . . . . . . 35

The INTERBUS ID Code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Data Exchange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

3

Image 3
Contents 890USE19600 Version Advantys STBPage Table of Contents Application Example Safety Information ProcedureImportant Information Safety Information Construed as a commitment by Schneider Electric About the BookAt a Glance Validity NoteAbout the Book Introduction Summary What’s in this Chapter?Topic Basic What Is Advantys STB?Introduction Island Bus I/OWhat Is a Network Interface Module? Structural About Interbus Outputs in 4 msComponents of a simplified Interbus network are shown below Topology Physical LayerOn the shift register ring on which data is circulated NodeAddressing Input and output data in the masters bufferIntroduction Chapter? Product specifications of the basic Interbus NIMSTB NIB Basic NIM Module What’s in thisHardware External Features of the STB NIB 1010 NIMFeatures Called out in the illustration below Feature FunctionSpace reserved for the network connectors NIM housing Connections STB NIB 1010 Fieldbus InterfaceSummary Fieldbus PortCable ConnectorsInterbus NetworkingIndications LED Physical DescriptionOverview GeneralLEDs NIM ActivityDescription Power Supply InterfaceIsland is the two-receptacle connector illustrated below PhysicalRight Use eitherImproper Galvanic Isolation Logic PowerExternal CharacteristicsPower Supply RequirementsTechnical Specifications STB NIB 1010 Module SpecificationsConfiguring the Island Bus Bus Address Basic island configurationAuto-Addressing About the IslandModule Physical Location Island Bus Address An ExampleAuto-Configuration ConfigurationAbout Auto Stage Been successfully configured at least onceRST Button Hinged coverHeartbeat Island Fallback ScenariosFallback ScenariosIntroduction What’s in this Chapter? Fieldbus Communications SupportData Type Interbus ID CodeLow High BytesData Length Objects Data ExchangeData and Status ObjectsBoundaries InternalProcess Image WordContains the NIM status Output DataInput Data ExchangeWith an Advantys STB NIB 1010 basic NIM Application ExampleSample Island Sample Island AssemblyAssembly Fieldbus networkModel Module Type Island Bus Address I/O modules have the following island bus addressesDevices on an Interbus network Network Configuration ConsiderationsFor use with an Advantys STB island ConnectionConsiderations Before YouBegin SyConStep Action Comment Using SyCon to Configure an STB Island on InterbusWith SyCon Stage DescriptionWorkspace To add the NIM to the network configurationConfiguring Add the NIMInstructions Create an EDSSaving Using CMD to Configure an STB Island on Interbus Island slave to your configuration using CMDCMD Downloading AddAdding Island SlaveApplication Example Glossary BOS ARPCRC CanCOB ComsEIA DhcpDIN EDSFedp EMCEMI EOSGSD FsdpIEC type 1 input BaseScanning IECInput response Industrial I/OInput filtering Input polarityNema Energized and open when the coil is energizedEnergized and closed when the coil is energized ContactNMT NIMPDM PDOPLC Profibus DP Process I/OProducer Consumer modelSDO RTDSAP ScadaSnmp SmmpsStdp TCPTFE Voltage group UDPVaristor Suppress transient voltage surgesIndex Interbus Heartbeat message, 34 housing ID codeIndex