Application Example

The I/O modules have the following island bus addresses:

I/O Model

Module Type

Island Bus Address

 

 

 

STB DDI 3230

two-channel digital input

1

 

 

 

STB DDO 3200

two-channel digital output

2

 

 

 

STB DDI 3425

four-channel digital input

3

 

 

 

STB DDO 3415

four-channel digital output

4

 

 

 

STB DDI 3615

six-channel digital input

5

 

 

 

STB DDO 3605

six-channel digital output

6

 

 

 

STB AVI 1275

two-channel analog input

7

 

 

 

STB AVO 1255

two-channel analog output

8

 

 

 

The NIM, the PDM, and the termination plate do not consume island bus addresses, and they do not exchange data with the fieldbus master.

890USE19600 April 2004

43

Image 43
Contents 890USE19600 Version Advantys STBPage Table of Contents Application Example Procedure Safety InformationImportant Information Safety Information Construed as a commitment by Schneider Electric About the BookAt a Glance Validity NoteAbout the Book Summary What’s in this Chapter? IntroductionTopic Basic What Is Advantys STB?Introduction Island Bus I/OWhat Is a Network Interface Module? Structural Outputs in 4 ms About InterbusComponents of a simplified Interbus network are shown below Topology Physical LayerOn the shift register ring on which data is circulated NodeAddressing Input and output data in the masters bufferIntroduction Chapter? Product specifications of the basic Interbus NIMSTB NIB Basic NIM Module What’s in thisHardware External Features of the STB NIB 1010 NIMFeatures Called out in the illustration below Feature FunctionSpace reserved for the network connectors NIM housing Connections STB NIB 1010 Fieldbus InterfaceSummary Fieldbus PortCable ConnectorsInterbus NetworkingIndications LED Physical DescriptionOverview GeneralLEDs NIM ActivityDescription Power Supply InterfaceIsland is the two-receptacle connector illustrated below PhysicalRight Use eitherImproper Galvanic Isolation Logic PowerExternal CharacteristicsPower Supply RequirementsTechnical Specifications STB NIB 1010 Module SpecificationsConfiguring the Island Bus Bus Address Basic island configurationAuto-Addressing About the IslandModule Physical Location Island Bus Address An ExampleConfiguration Auto-ConfigurationAbout Auto Stage Been successfully configured at least onceRST Button Hinged coverHeartbeat Island Fallback ScenariosFallback ScenariosIntroduction What’s in this Chapter? Fieldbus Communications SupportData Type Interbus ID CodeLow High BytesData Length Objects Data ExchangeData and Status ObjectsBoundaries InternalProcess Image WordContains the NIM status Output DataInput Data ExchangeWith an Advantys STB NIB 1010 basic NIM Application ExampleSample Island Sample Island AssemblyAssembly Fieldbus networkModel Module Type Island Bus Address I/O modules have the following island bus addressesDevices on an Interbus network Network Configuration ConsiderationsFor use with an Advantys STB island ConnectionConsiderations Before YouBegin SyConStep Action Comment Using SyCon to Configure an STB Island on InterbusWith SyCon Stage DescriptionWorkspace To add the NIM to the network configurationConfiguring Add the NIMInstructions Create an EDSSaving Island slave to your configuration using CMD Using CMD to Configure an STB Island on InterbusCMD Downloading AddAdding Island SlaveApplication Example Glossary BOS ARPCRC CanCOB ComsEIA DhcpDIN EDSFedp EMCEMI EOSGSD FsdpIEC type 1 input BaseScanning IECInput response Industrial I/OInput filtering Input polarityNema Energized and open when the coil is energizedEnergized and closed when the coil is energized ContactNMT NIMPDO PDMPLC Profibus DP Process I/OProducer Consumer modelSDO RTDSAP ScadaSnmp SmmpsTCP StdpTFE Voltage group UDPVaristor Suppress transient voltage surgesIndex Interbus Heartbeat message, 34 housing ID codeIndex