Schneider Electric 890USE19600 Version 1.0 manual Sample Island Assembly, Fieldbus network

Page 42

Application Example

Sample Island Assembly

Introduction

The configuration example(s) in this chapter use a particular Advantys STB island

 

assembly, described below. Your island assembly is independent of the network’s

 

master scanner because the island is represented by the NIM as a single node on

 

the fieldbus network.

Sample Island

 

The sample I/O system used in this chapter’s application example(s) implements a

Assembly

variety of analog and digital modules.

1STB NIB 1010 INTERBUS NIM

2STB PDT 3100 24 VDC PDM

3STB DDI 3230 two-channel 24 VDC digital input module (2 bits of data, 2 bits of status)

4STB DDO 3200 two-channel 24 VDC digital output module (2 bits of data, 2 bits of echo output data, 2 bits of status)

5STB DDI 3425 four-channel 24 VDC digital input module (4 bits of data, 4 bits of status)

6STB DDO 3415 four-channel 24 VDC digital output module (4 bits of data, 4 bits of echo output data, 4 bits of status)

7STB DDI 3615 six-channel 24 VDC digital input module (6 bits of data, 6 bits of status)

8STB DDO 3605 six-channel 24 VDC digital output module (6 bits of data, 6 bits of echo output data, 6 bits of status)

9STB AVI 1275 two-channel +/-10 VDC analog input module (16 bits of data [channel 1], 16 bits of data [channel 2], 8 bits of status [channel 1], 8 bits of status [channel 2])

10STB AVO 1255 two-channel 0 ... 10 VDC analog output module (8 bits of status [channel 1], 8 bits of status [channel 2], 16 bits of data [channel 1], 16 bits of data [channel 2])

11STB XMP 1100 termination plate

42

890USE19600 April 2004

Image 42
Contents Advantys STB 890USE19600 VersionPage Table of Contents Application Example Safety Information ProcedureImportant Information Safety Information Validity Note About the BookAt a Glance Construed as a commitment by Schneider ElectricAbout the Book Introduction Summary What’s in this Chapter?Topic Island Bus I/O What Is Advantys STB?Introduction BasicWhat Is a Network Interface Module? Structural About Interbus Outputs in 4 msComponents of a simplified Interbus network are shown below Physical Layer TopologyInput and output data in the masters buffer NodeAddressing On the shift register ring on which data is circulatedIntroduction What’s in this Product specifications of the basic Interbus NIMSTB NIB Basic NIM Module Chapter?Feature Function External Features of the STB NIB 1010 NIMFeatures Called out in the illustration below HardwareSpace reserved for the network connectors NIM housing Fieldbus Port STB NIB 1010 Fieldbus InterfaceSummary ConnectionsNetworking ConnectorsInterbus CableGeneral LED Physical DescriptionOverview IndicationsNIM Activity LEDsPhysical Power Supply InterfaceIsland is the two-receptacle connector illustrated below DescriptionUse either RightLogic Power Improper Galvanic IsolationRequirements CharacteristicsPower Supply ExternalSTB NIB 1010 Module Specifications Technical SpecificationsConfiguring the Island Bus About the Island Basic island configurationAuto-Addressing Bus AddressAn Example Module Physical Location Island Bus AddressAuto-Configuration ConfigurationAbout Auto Hinged cover Been successfully configured at least onceRST Button StageScenarios Island Fallback ScenariosFallback HeartbeatFieldbus Communications Support Introduction What’s in this Chapter?High Bytes Interbus ID CodeLow Data TypeData Length Objects Data ExchangeData and Status ObjectsWord InternalProcess Image BoundariesExchange Output DataInput Data Contains the NIM statusApplication Example With an Advantys STB NIB 1010 basic NIMFieldbus network Sample Island AssemblyAssembly Sample IslandI/O modules have the following island bus addresses Model Module Type Island Bus AddressConnection Network Configuration ConsiderationsFor use with an Advantys STB island Devices on an Interbus networkSyCon Before YouBegin ConsiderationsStage Description Using SyCon to Configure an STB Island on InterbusWith SyCon Step Action CommentAdd the NIM To add the NIM to the network configurationConfiguring WorkspaceCreate an EDS InstructionsSaving Using CMD to Configure an STB Island on Interbus Island slave to your configuration using CMDCMD Island Slave AddAdding DownloadingApplication Example Glossary ARP BOSComs CanCOB CRCEDS DhcpDIN EIAEOS EMCEMI FedpFsdp GSDIEC BaseScanning IEC type 1 inputInput polarity Industrial I/OInput filtering Input responseContact Energized and open when the coil is energizedEnergized and closed when the coil is energized NemaNIM NMTPDM PDOPLC Consumer model Process I/OProducer Profibus DPScada RTDSAP SDOSmmps SnmpStdp TCPTFE Suppress transient voltage surges UDPVaristor Voltage groupIndex Heartbeat message, 34 housing ID code InterbusIndex