Glossary

 

 

STD_P

standard profile. On a Fipio network, a standard profile is a fixed set of configuration

 

and operating parameters for an agent device, based on the number of modules that

 

the device contains and the device’s total data length. Three types of standard

 

profiles are available—Fipio reduced device profile (FRD_P), Fipio standard device

 

profile (FSD_P), and the Fipio extended device profile (FED_P).

stepper motor

A specialized DC motor that allows discrete positioning without feedback.

subnet

A part of a network that shares a network address with the other parts of a network.

 

A subnet may be physically and/or logically independent of the rest of the network.

 

A part of an internet address called a subnet number, which is ignored in IP routing,

 

distinguishes the subnet.

surge

The process of absorbing and clipping voltage transients on an incoming AC line or

suppression

control circuit. Metal-oxide varistors and specially designed RC networks are

 

frequently used as surge suppression mechanisms.

 

 

T

TC

thermocouple. A TC device is a bimetallic temperature transducer that provides a

 

temperature value by measuring the voltage differential caused by joining together

 

two different metals at different temperatures.

TCP

transmission control protocol. A connection-oriented transport layer protocol that

 

provides reliable full-duplex data transmission. TCP is part of the TCP/IP suite of

 

protocols.

telegram

A data packet used in serial communication.

TFE

transparent factory Ethernet. Schneider Electric’s open automation framework

 

based on TCP/IP.

Tx

transmission. For example, in a CAN-based network, a PDO is described as a

 

TxPDO of the device that transmits it.

 

 

890USE19600 April 2004

67

Image 67
Contents 890USE19600 Version Advantys STBPage Table of Contents Application Example Procedure Safety InformationImportant Information Safety Information Construed as a commitment by Schneider Electric About the BookAt a Glance Validity NoteAbout the Book Summary What’s in this Chapter? IntroductionTopic Basic What Is Advantys STB?Introduction Island Bus I/OWhat Is a Network Interface Module? Structural Outputs in 4 ms About InterbusComponents of a simplified Interbus network are shown below Topology Physical LayerOn the shift register ring on which data is circulated NodeAddressing Input and output data in the masters bufferIntroduction Chapter? Product specifications of the basic Interbus NIMSTB NIB Basic NIM Module What’s in thisHardware External Features of the STB NIB 1010 NIMFeatures Called out in the illustration below Feature FunctionSpace reserved for the network connectors NIM housing Connections STB NIB 1010 Fieldbus InterfaceSummary Fieldbus PortCable ConnectorsInterbus NetworkingIndications LED Physical DescriptionOverview GeneralLEDs NIM ActivityDescription Power Supply InterfaceIsland is the two-receptacle connector illustrated below PhysicalRight Use eitherImproper Galvanic Isolation Logic PowerExternal CharacteristicsPower Supply RequirementsTechnical Specifications STB NIB 1010 Module SpecificationsConfiguring the Island Bus Bus Address Basic island configurationAuto-Addressing About the IslandModule Physical Location Island Bus Address An ExampleConfiguration Auto-ConfigurationAbout Auto Stage Been successfully configured at least onceRST Button Hinged coverHeartbeat Island Fallback ScenariosFallback ScenariosIntroduction What’s in this Chapter? Fieldbus Communications SupportData Type Interbus ID CodeLow High BytesData Length Objects Data ExchangeData and Status ObjectsBoundaries InternalProcess Image WordContains the NIM status Output DataInput Data ExchangeWith an Advantys STB NIB 1010 basic NIM Application ExampleSample Island Sample Island AssemblyAssembly Fieldbus networkModel Module Type Island Bus Address I/O modules have the following island bus addressesDevices on an Interbus network Network Configuration ConsiderationsFor use with an Advantys STB island ConnectionConsiderations Before YouBegin SyConStep Action Comment Using SyCon to Configure an STB Island on InterbusWith SyCon Stage DescriptionWorkspace To add the NIM to the network configurationConfiguring Add the NIMInstructions Create an EDSSaving Island slave to your configuration using CMD Using CMD to Configure an STB Island on InterbusCMD Downloading AddAdding Island SlaveApplication Example Glossary BOS ARPCRC CanCOB ComsEIA DhcpDIN EDSFedp EMCEMI EOSGSD FsdpIEC type 1 input BaseScanning IECInput response Industrial I/OInput filtering Input polarityNema Energized and open when the coil is energizedEnergized and closed when the coil is energized ContactNMT NIMPDO PDMPLC Profibus DP Process I/OProducer Consumer modelSDO RTDSAP ScadaSnmp SmmpsTCP StdpTFE Voltage group UDPVaristor Suppress transient voltage surgesIndex Interbus Heartbeat message, 34 housing ID codeIndex